First script function is to obtain the end-user's browser and browser version.
Second script function is to display the links to NIST home page, NIST data home page, ITS-90 home page, and NIST other online databases using the HTML table for format.
Type S Thermocouples -- coefficients, ci , of reference equations giving the thermoelectric voltage, E, as a function of temperature, t90 , for the indicated temperature ranges. The equations are of the form:
where E is in mV and t90 is in °C.
First script function is to setup the table attributes based on the end-user browser and browser version.
Display the HTML table tag and attributes using JavaScript.
Third function is to display the table caption.
-50 °C to 1064.18 °C
1064.18 °C to 1664.5 °C
1664.5 °C to 1768.1 °C
c0 =
0.000000000000
x100
0.132900444085
x101
0.146628232636
x103
c1 =
0.540313308631
x10-2
0.334509311344
x10-2
-0.258430516752
x100
c2 =
0.125934289740
x10-4
0.654805192818
x10-5
0.163693574641
x10-3
c3 =
-0.232477968689
x10-7
-0.164856259209
x10-8
-0.330439046987
x10-7
c4 =
0.322028823036
x10-10
0.129989605174
x10-13
-0.943223690612
x10-14
c5 =
-0.331465196389
x10-13
c6 =
0.255744251786
x10-16
c7 =
-0.125068871393
x10-19
c8 =
0.271443176145
x10-23
First script function is to display the copyright information.
Second script function is to display the links to NIST home page, NIST Data home page, and NIST other online databases.
Third script function is to display the message identifying NIST as an agency of the U.S. Commerce Department’s Technology Administration.
Fourth script function is to display the message "For comments and questions" and the email address to which comments and questions can be sent.
Fifth script function is to display the date the web page is created.
Sixth script function is to display the date and time the web page is last modified.
Seventh script function is to display the "Section 508 compliant requirements of the Workforce Investment Act & Americans With Disabilities Act" statement.