NIST High Temp. Superconducting Materials (HTS) Database:

NIST Standard Reference Database 62

Last Update to Data Content: 1996

DOI: https://doi.org/10.18434/T4KP8J


Bibliographic Information

Title: Localization and Interaction Effects During Superconductor- Insulator Transition of Bi2Sr2Ca1-xGdxCu2O8+d
Author(s): B. Jayaram, P.C. Lanchester, and M.T. Weller
Publication: Physical Review B Volume: 43 Issue: 7 Year: 1991 Page(s): 5444-5450
Editor(s): Not Available
Publisher: American Physical Society
Language: English
Notes: Not Available
Keywords: Material Specification, Critical Temperature, Resistivity (normal state), Magnetic Susceptibility

Materials and Properties

Bi:2212; [Bi-Sr-Ca(Gd)-Cu-O]
Material Specification for Bi:2212; [Bi-Sr-Ca(Gd)-Cu-O] Process: Solid State Reaction
Notes: "Samples... were prepared by solid-state reaction of appropriate quantities of well-mixed metal oxides and carbonates which were reacted at 850 °C for 72 h. The reacted materials were pulverized and cold pressed into pellets which were sintered and annealed in air or oxygen in the temperature range 860-910 °C. One set of air-annealed samples is further annealed in nitrogen at 650 °C. A second set of samples is quenched in liquid nitrogen."
Formula: Bi2Sr2Ca1-xGdxCu2O8+x
Informal Name: Bi:2212
Chemical Family: Bi-Sr-Ca(Gd)-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:

Critical Temperature for Bi:2212; [Bi-Sr-Ca(Gd)-Cu-O]
Treatment () Environment () x of Gdx (formula units) Critical Temperature (K)
annealed air 0.10 73
annealed air 0.30 75
annealed air 0.32 71
annealed air 0.40 61
annealed air 0.45 50
annealed air 0.50 34
annealed air 0.55 18
annealed oxygen 0.00 73
annealed oxygen 0.10 65
annealed oxygen 0.20 74
annealed oxygen 0.30 65
annealed oxygen 0.40 63
annealed oxygen 0.45 56
annealed oxygen 0.50 37
annealed oxygen 0.55 24
annealed oxygen 0.60 5
quenched liquid N2 0.00 81
quenched liquid N2 0.10 62
quenched liquid N2 0.20 47
quenched liquid N2 0.30 31
quenched liquid N2 0.40 13
annealed nitrogen 0.10 75
annealed nitrogen 0.30 68
annealed nitrogen 0.40 41
annealed nitrogen 0.45 25
Measurement Method: Four-probe method
"Four-probe dc resistivity data of rectangular slab samples were collected..." No additional measurement details were noted.

Cautions: Evaluated Data
Digitized data were obtained from Figure 2a of the paper.
Resistivity (normal state) for Bi:2212; [Bi-Sr-Ca(Gd)-Cu-O]
x of Gdx (formula units) Treatment () Environment () Temperature (K) Resistivity (normal state) (mΩ·cm)
0 quenched liquid N2 68 0.01
0 quenched liquid N2 74 0.01
0 quenched liquid N2 79 0.13
0 quenched liquid N2 81 0.29
0 quenched liquid N2 85 0.60
0 quenched liquid N2 86 0.76
0 quenched liquid N2 88 1.05
0 quenched liquid N2 92 1.43
0 quenched liquid N2 107 1.63
0 quenched liquid N2 126 1.77
0 quenched liquid N2 154 1.87
0 quenched liquid N2 184 1.99
0 quenched liquid N2 210 2.09
0 quenched liquid N2 242 2.19
0 quenched liquid N2 266 2.25
0 quenched liquid N2 297 2.34
0.4 annealed oxygen 60 0.02
0.4 annealed oxygen 67 0.07
0.4 annealed oxygen 74 0.59
0.4 annealed oxygen 82 1.06
0.4 annealed oxygen 87 1.64
0.4 annealed oxygen 92 2.05
0.4 annealed oxygen 120 2.50
0.4 annealed oxygen 163 3.06
0.4 annealed oxygen 206 3.50
0.4 annealed oxygen 239 3.83
0.4 annealed oxygen 290 4.27
0.45 annealed air 49 0.02
0.45 annealed air 57 0.19
0.45 annealed air 71 1.00
0.45 annealed air 83 1.62
0.45 annealed air 92 1.97
0.45 annealed air 123 2.30
0.45 annealed air 168 2.67
0.45 annealed air 209 2.99
0.45 annealed air 252 3.25
0.45 annealed air 297 3.56
0.4 quenched liquid N2 38 0.03
0.4 quenched liquid N2 45 0.09
0.4 quenched liquid N2 51 0.78
0.4 quenched liquid N2 65 2.17
0.4 quenched liquid N2 81 3.10
0.4 quenched liquid N2 90 3.62
0.4 quenched liquid N2 113 4.01
0.4 quenched liquid N2 140 4.34
0.4 quenched liquid N2 191 4.90
0.4 quenched liquid N2 235 5.33
0.4 quenched liquid N2 276 5.66
0.4 quenched liquid N2 298 5.81
0.5 annealed air 32 0.03
0.5 annealed air 35 0.09
0.5 annealed air 42 0.84
0.5 annealed air 50 1.76
0.5 annealed air 64 2.86
0.5 annealed air 81 3.66
0.5 annealed air 104 4.05
0.5 annealed air 135 4.37
0.5 annealed air 176 4.80
0.5 annealed air 219 5.29
0.5 annealed air 263 5.72
0.5 annealed air 295 6.10
0.45 quenched liquid N2 23 0.02
0.45 quenched liquid N2 29 0.04
0.45 quenched liquid N2 32 0.68
0.45 quenched liquid N2 42 3.77
0.45 quenched liquid N2 51 5.34
0.45 quenched liquid N2 60 6.45
0.45 quenched liquid N2 75 7.20
0.45 quenched liquid N2 105 7.35
0.45 quenched liquid N2 143 7.56
0.45 quenched liquid N2 172 7.83
0.45 quenched liquid N2 199 8.11
0.45 quenched liquid N2 239 8.49
0.45 quenched liquid N2 291 8.98
Measurement Method: Four-probe method
"Four-probe dc resistivity data of rectangular slab samples were collected..." No additional measurement details were noted.

Cautions: Evaluated Data
Digitized data were obtained from Figure 1a of the paper.
Magnetic Susceptibility for Bi:2212; [Bi-Sr-Ca(Gd)-Cu-O]
x of Gdx (formula units) Treatment () Environment () Temperature (K) Magnetic Susceptibility (arbitrary)
0 quenched liquid N2 12 -1.57
0 quenched liquid N2 24 -1.52
0 quenched liquid N2 37 -1.51
0 quenched liquid N2 48 -1.46
0 quenched liquid N2 58 -1.36
0 quenched liquid N2 64 -1.14
0 quenched liquid N2 68 -0.70
0 quenched liquid N2 71 -0.21
0 quenched liquid N2 73 -0.01
0 quenched liquid N2 79 0.00
0.4 annealed oxygen 11 -5.36
0.4 annealed oxygen 18 -5.36
0.4 annealed oxygen 28 -5.32
0.4 annealed oxygen 42 -5.24
0.4 annealed oxygen 51 -4.95
0.4 annealed oxygen 56 -3.89
0.4 annealed oxygen 60 -1.06
0.4 annealed oxygen 62 -0.04
0.4 annealed oxygen 66 0.00
0.45 annealed air 12 -5.12
0.45 annealed air 25 -5.08
0.45 annealed air 38 -4.87
0.45 annealed air 41 -4.63
0.45 annealed air 44 -4.18
0.45 annealed air 46 -2.66
0.45 annealed air 48 -1.15
0.45 annealed air 50 -0.04
0.45 annealed air 53 0.00
0.4 quenched liquid N2 12 -4.58
0.4 quenched liquid N2 22 -4.58
0.4 quenched liquid N2 28 -4.46
0.4 quenched liquid N2 31 -4.26
0.4 quenched liquid N2 35 -3.15
0.4 quenched liquid N2 37 -1.02
0.4 quenched liquid N2 40 -0.08
0.4 quenched liquid N2 43 0.00
0.5 annealed air 11 -5.12
0.5 annealed air 17 -5.04
0.5 annealed air 20 -4.87
0.5 annealed air 26 -3.85
0.5 annealed air 28 -1.51
0.5 annealed air 30 -0.08
0.5 annealed air 33 0.00
0.45 quenched liquid N2 11 -4.87
0.45 quenched liquid N2 16 -4.83
0.45 quenched liquid N2 19 -4.71
0.45 quenched liquid N2 20 -3.60
0.45 quenched liquid N2 22 -1.19
0.45 quenched liquid N2 23 -0.49
0.45 quenched liquid N2 24 -0.04
0.45 quenched liquid N2 25 0.00
Measurement Method: Ac susceptibility
"Ac susceptibility measurements were performed using a home-built system." No additional measurement details were noted.

Cautions: Evaluated Data
Digitized data were obtained from Figure 1b of the paper.