NIST High Temp. Superconducting Materials (HTS) Database:

NIST Standard Reference Database 62

Last Update to Data Content: 1996

DOI: https://doi.org/10.18434/T4KP8J


Bibliographic Information

Title: Determination of H (T) on a Y2Ba4Cu8O16 Single Crystal
Author(s): J.C. Martinez, J.J. Prejean, J. Karpinski, E. Kaldis, and P. Bordet
Publication: Solid State Communications Volume: 75 Issue: 4 Year: 1990 Page(s): 315-318
Editor(s): Not Available
Publisher: Pergamon Press Ltd
Language: English
Notes: Not Available
Keywords: Material Specification, Critical Temperature, Critical Field Strength Hc1

Materials and Properties

Y:124; [Y-Ba-Cu-O]
Material Specification for Y:124; [Y-Ba-Cu-O] Process: Flux Growth
Notes: The authors cite J. Karpinski et al., J. Less Common Metals, Vol. 150, 129 (1989), and summarize the procedure as follows. "Single crystals have been grown by a high pressure flux method... The magnetic measurements were performed on a single crystal platelet (0.8x0.5x0.07 mm3)."
Formula: YBa2Cu4O8
Informal Name: Y:124
Chemical Family: Y-Ba-Cu-O
Chemical Class: Oxide
Structure Type: Single Crystal
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:

Critical Temperature for Y:124; [Y-Ba-Cu-O]
Critical Temperature (K) 74
Measurement Method: Dc-magnetometer
"For this work we choose the classical method (to determine)... H (T) from the deviation from linearity in M(H) curves. We used an extraction dc-magnetometer... The calibration of the moment has been obtained by measuring the signal of a very pure (99.999%) sphere of lead... Using a superconducting Nb-Ti coil we applied field up to (19.9 kA/m)... For all measurements we waited about 30 minutes above Tc. Subsequently we cooled the sample at zero field, down to the temperture..."

Cautions: Evaluated Data
Critical Field Strength Hc1 for Y:124; [Y-Ba-Cu-O]
Field Direction () Temperature (K) Crit.Mag.Field Strength Hc1 (kA/m)
H//a 10 3.6
H//a 20 3.2
H//a 30 3.1
H//a 40 2.7
H//a 50 2.5
H//a 60 1.7
H//a 65 1.1
H//b 10 4.6
H//b 20 3.4
H//b 40 3.9
H//b 49 2.3
H//b 60 1.9
H//b 65 1.5
H//c 11 19.9
H//c 20 14.0
H//c 30 13.3
H//c 41 11.8
H//c 50 8.7
H//c 61 5.5
H//c 65 2.4
H//c 67 3.1
H//c 70 2.6
H//c 74 0
Measurement Method: Dc-magnetometer
"For this work we choose the classical method (to determine)... H (T) from the deviation from linearity in M(H) curves. We used an extraction dc-magnetometer... The calibration of the moment has been obtained by measuring the signal of a very pure (99.999%) sphere of lead... Using a superconducting Nb-Ti coil we applied field up to (19.9 kA/m)... For all measurements we waited about 30 minutes above Tc. Subsequently we cooled the sample at zero field, down to the temperture..."

Cautions: Evaluated Data
Digitized data were obtained from Figure 5 of the paper.