NIST High Temp. Superconducting Materials (HTS) Database:

NIST Standard Reference Database 62

Last Update to Data Content: 1996

DOI: https://doi.org/10.18434/T4KP8J


Bibliographic Information

Title: Anomalous Thermoelectric Power of Bi1.6Pb0.5Sr1.9-yLayCu1.05Oz
Author(s): M. Sera, S. Tanaka, M. Sato, and H. Fujishita
Publication: Solid State Communications Volume: 81 Issue: 5 Year: 1992 Page(s): 415-417
Editor(s): Not Available
Publisher: Pergamon Press Ltd
Language: English
Notes: Not Available
Keywords: Material Specification, Resistivity (normal state), Thermoelectric Power

Materials and Properties

Bi:221; [Bi(Pb)-Sr(La)-Cu-O]
Material Specification for Bi:221; [Bi(Pb)-Sr(La)-Cu-O] Process: Solid State Reaction
Notes: "Mixtures of powder of Bi2O3, PbO, SrCO3, La2O3 and CuO were fired at 800 °C for 20 h, reground, fired at 800 °C for 20 h, pressed into pellets, sintered at 810 °C for 20 h and cooled in the furnace."
Formula: Bi1.6Pb0.5Sr1.9-xLaxCu1.05Oy
Informal Name: Bi:221
Chemical Family: Bi(Pb)-Sr(La)-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:

Resistivity (normal state) for Bi:221; [Bi(Pb)-Sr(La)-Cu-O]
x of Lax (formula units) Temperature (K) Resistivity (normal state) (mΩ·cm)
0.0 7 2.1
0.0 20 2.0
0.0 63 2.0
0.0 126 2.2
0.0 185 2.4
0.0 235 2.6
0.0 277 3.0
0.1 5 0.0
0.1 8 0.1
0.1 13 0.1
0.1 18 1.2
0.1 66 1.4
0.1 127 2.0
0.1 180 2.0
0.1 230 2.2
0.1 286 2.4
0.5 19 0.1
0.5 21 0.6
0.5 23 1.3
0.5 28 2.0
0.5 68 2.3
0.5 118 2.7
0.5 190 3.1
0.5 282 3.7
Measurement Method: Four-probe method
"The electrical resistivity... was measured by a usual four probe method." No additional measurement details were noted.

Cautions: Unevaluated Data
Digitized data were obtained from Figure 1 of the paper.
Thermoelectric Power for Bi:221; [Bi(Pb)-Sr(La)-Cu-O]
x of Lax (formula units) Temperature (K) Thermoelectric Power (µV/K)
0.0 9 - 0.6
0.0 50 -10.9
0.0 100 -18.0
0.0 150 -20.2
0.0 200 -21.8
0.0 250 -23.5
0.0 300 -24.6
0.5 26 - 0.1
0.5 50 0.5
0.5 100 3.7
0.5 150 3.1
0.5 200 1.4
0.5 250 - 1.3
0.5 300 - 4.1
1.0 20 10.2
1.0 50 28.6
1.0 100 48.5
1.0 150 59.3
1.0 200 63.6
1.0 250 63.5
1.0 300 60.2
Measurement Method: Thermopower method
"The thermoelectric power S was measured by a dc method where a temperature gradient between both ends of the sample was 0.2 K - 0.8 K depending on the temperature region." No additional measurement details were noted.

Cautions: Evaluated Data
Digitized data were obtained from Figure 2 of the paper.