NIST High Temp. Superconducting Materials (HTS) Database:

NIST Standard Reference Database 62

Last Update to Data Content: 1996

DOI: https://doi.org/10.18434/T4KP8J


Bibliographic Information

Title: Heat Capacity of High-Purity Polycrystalline YBa2Cu3O7 from 0.4 to 400 K in Applied Magnetic Fields of 0 and 70 kG
Author(s): W.C. Lee, K. Sun, L.L. Miller, D.C. Johnston, R.A. Klemm, S. Kim, R.A. Fisher, and N.E. Phillips
Publication: Physical Review B Volume: 43 Issue: 1 Year: 1991 Page(s): 463-472
Editor(s): Not Available
Publisher: American Physical Society
Language: English
Notes: Not Available
Keywords: Material Specification, Crystallography, Specific Heat

Materials and Properties

Y:123; [Y-Ba-Cu-O]
Material Specification for Y:123; [Y-Ba-Cu-O] Process: Solid State Reaction
Notes: "A 15-g master batch... was prepared from predried 99.99% Y2O3, 99.999% CuO, and 99.9% BaCO3. The stoichiometric mixture of starting materials was ground thoroughly in air using an agate mortar and pestle, and fired at 940 °C for 1 day in air in an alumina crucible. Then 12 g was pressed into a (1.27 cm = 0.5 in) diameter pellet... samples were fired at 940 °C for 90 days in air with ten intermediate grindings, followed by heating in O2 at 640 °C for 1 day and oven cooling to room temperature."
Formula: YBa2Cu3O7
Informal Name: Y:123
Chemical Family: Y-Ba-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:

Crystallography for Y:123; [Y-Ba-Cu-O]
Crystal System: Orthorhombic
Formula Units per Cell:
Space Group:
Cell Parameters
Temp K a Å b Å c Å
296 3.712(2) 3.895(4) 11.685(4)
Measurement Method: X-ray diffraction
"From powder x-ray diffraction analysis, the batch... was single phase." No additional measurement details were noted.

Cautions: Unevaluated Data
Specific Heat for Y:123; [Y-Ba-Cu-O]
Magnetic Field (T) Temperature (K) Specific Heat (J kg-1 K-1)
7 0.3 0.003
7 1.5 0.02
7 1.9 0.04
7 3.2 0.07
7 4.3 0.11
7 5.6 0.20
7 7.5 0.40
7 9.0 0.69
0 0.2 0.002
0 2.1 0.04
0 2.6 0.05
0 3.2 0.07
0 3.9 0.09
0 5.7 0.20
0 7.5 0.40
0 8.9 0.68
Measurement Method: Pulse calorimetry
"Heat-capacity C(T) measurements were carried out on the pellet sample... using pulse calorimeters... at Berkeley (0.4-30 K, accuracy of... 0.3%)." No additional measurement details were noted.

Cautions: Evaluated Data
Digitized data were obtained from Figure 5 of the paper.