Material Specification for Tl:2223; [Tl-Ba-Ca-Cu-O]
Process: Solid State Reaction
Notes: The authors cite T. Zetterer et al., Phys. Rev. B, Vol. 41, 9499 (1990), and summarize the procedure as follows. "Polycrystalline samples... have been prepared... The sample used for the measurements is almost single phase with only spurious amounts of the Tl-2212 phase according to X-ray diffraction."
Formula: Tl2Ba2Ca2Cu3O10
Informal Name: Tl:2223
Chemical Family: Tl-Ba-Ca-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:
Resistivity (normal state) for Tl:2223; [Tl-Ba-Ca-Cu-O]
Magnetic Field (T) |
Temperature (K) |
Resistivity (normal state) (mΩ·cm) |
0 |
60 |
0.0 |
0 |
100 |
0.0 |
0 |
115 |
0.0 |
0 |
120 |
0.3 |
0 |
140 |
0.6 |
0 |
200 |
0.9 |
0.5 |
60 |
0.0 |
0.5 |
95 |
0.0 |
0.5 |
113 |
0.1 |
0.5 |
120 |
0.3 |
0.5 |
140 |
0.6 |
0.5 |
200 |
0.9 |
1.0 |
60 |
0.0 |
1.0 |
87 |
0.0 |
1.0 |
110 |
0.1 |
1.0 |
120 |
0.3 |
1.0 |
140 |
0.6 |
1.0 |
200 |
0.9 |
3 |
60 |
0.0 |
3 |
69 |
0.0 |
3 |
110 |
0.1 |
3 |
120 |
0.3 |
3 |
140 |
0.6 |
3 |
200 |
0.9 |
Measurement Method: Four-probe method
"For the measurements of the Hall-effect and the resistivity the sample was cut into a parallelepiped of dimensions 5.11 x 1.99 x 2.06 mm
-3. Contacts were attached with silver adhesive (contact resistances were below 2Ω). The current contacts covered two opposite sides of the sample, in order to provide a "uniform" current flow. The Hall-voltage was measured by a standard 4-probe lock-in technique with an electrical current j = 10 mA at f = 120 Mhz. (The magnetic field was applied perpendicular to the electric current.) The measurements were performed at a fixed temperature (held constant within 0.1 K) by sweeping the magnetic field at a constant rate of about 0.5 T/min."
Cautions: Evaluated Data
Digitized data were obtained from Figure 1 of the paper.
Hall Coefficient for Tl:2223; [Tl-Ba-Ca-Cu-O]
Magnetic Field (T) |
Temperature (K) |
Hall Coefficient (mm3 /C) |
0.5 |
82 |
-0.18 |
0.5 |
89 |
-0.34 |
0.5 |
98 |
-0.11 |
0.5 |
103 |
-0.52 |
0.5 |
104 |
-0.27 |
0.5 |
105 |
-0.62 |
0.5 |
107 |
-0.67 |
0.5 |
114 |
-3.42 |
0.5 |
117 |
-3.97 |
0.5 |
120 |
-1.30 |
0.5 |
122 |
0.88 |
0.5 |
131 |
3.30 |
1.5 |
82 |
-0.18 |
1.5 |
93 |
-0.14 |
1.5 |
98 |
0.05 |
1.5 |
103 |
-0.20 |
1.5 |
108 |
-0.85 |
1.5 |
113 |
-1.75 |
1.5 |
116 |
-1.86 |
1.5 |
120 |
0.18 |
1.5 |
122 |
1.57 |
1.5 |
130 |
3.94 |
2.5 |
82 |
-0.18 |
2.5 |
89 |
0.01 |
2.5 |
98 |
0.24 |
2.5 |
110 |
-0.52 |
2.5 |
113 |
-1.32 |
2.5 |
120 |
1.05 |
2.5 |
122 |
1.99 |
2.5 |
131 |
3.92 |
3 |
83 |
0.00 |
3 |
89 |
0.18 |
3 |
94 |
0.15 |
3 |
98 |
0.42 |
3 |
108 |
0.30 |
3 |
113 |
-0.90 |
3 |
119 |
0.93 |
3 |
122 |
2.18 |
3 |
131 |
3.97 |
4 |
82 |
0.09 |
4 |
89 |
0.35 |
4 |
93 |
0.26 |
4 |
103 |
0.86 |
4 |
111 |
0.12 |
4 |
113 |
-0.31 |
4 |
117 |
1.08 |
4 |
122 |
2.41 |
4 |
131 |
3.92 |
5 |
82 |
0.14 |
5 |
90 |
0.47 |
5 |
93 |
0.34 |
5 |
103 |
1.24 |
5 |
110 |
0.48 |
5 |
113 |
0.14 |
5 |
118 |
1.55 |
5 |
121 |
2.42 |
5 |
131 |
3.92 |
Measurement Method: Four-probe method
"For the measurements of the Hall-effect and the resistivity the sample was cut into a parallelepiped of dimensions 5.11 x 1.99 x 2.06 mm
-3. Contacts were attached with silver adhesive (contact resistances were below 2Ω). The current contacts covered two opposite sides of the sample, in order to provide a "uniform" current flow. The Hall-voltage was measured by a standard 4-probe lock-in technique with an electrical current j = 10 mA at f = 120 Mhz. (The magnetic field was applied perpendicular to the electric current.) The measurements were performed at a fixed temperature (held constant within 0.1 K) by sweeping the magnetic field at a constant rate of about 0.5 T/min."
Cautions: Evaluated Data
Digitized data were obtained from Figure 3a and 3b of the paper.
Thermal Conductivity for Tl:2223; [Tl-Ba-Ca-Cu-O]
Temperature (K) |
Thermal Conductivity (W m-1 K-1) |
0 |
0 |
30 |
2.1 |
80 |
4.1 |
100 |
4.4 |
120 |
4.4 |
200 |
5.1 |
280 |
6.5 |
Measurement Method: Unknown thermal conductivity method
Cautions: Unevaluated Data
No measurement details were noted.