Material Specification for Y:123; [Y(Pr)-Ba-Cu-O]
Process: Solid State Reaction
Notes: "Specimens... were prepared by solid state reaction of the appropriate amounts of high purity (99.99% or better) Y2O3, Pr6O11BaCO3, and CuO. All of the oxides were dried overnight at 800 °C prior to use... The BaCO3 was dried overnight at 150 °C. The powders were weighed, ground with an agate mortar and pestle, and placed as a powder in an Al2O3 crucible. The powder was fired for 24 h in air at 930 °C. Four additional firings for 24 h intervals with intermediate regrindings were performed. Subsequently, the specimens were fired for two, four and six days with intermediate grindings, followed by a final grinding before the specimens were pressed into pellets. The pellets were annealed in (0.1 MPa = 1 atm) of oxygen for two days at 955-970 °C followed by slow cooling at 1 °C/min to 450 °C where they remained for 18 h before a final slow cool to room temperature."
Formula: Y1-xPrxBa2Cu3Oy
Informal Name: Y:123
Chemical Family: Y(Pr)-Ba-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:
Critical Temperature for Y:123; [Y(Pr)-Ba-Cu-O]
x of Prx (formula units) |
y of Oy (formula units) |
ΔTc (90%-10%) (K) |
Critical Temperature (K) |
0 |
6.96 |
0.7 |
92.0 |
0.05 |
6.96 |
0.7 |
91.4 |
0.10 |
6.97 |
0.9 |
87.7 |
0.15 |
6.97 |
1.4 |
81.3 |
0.20 |
6.96 |
1.9 |
74.0 |
0.30 |
6.97 |
2.6 |
58.3 |
0.40 |
6.98 |
3.5 |
44.1 |
0.50 |
6.95 |
6.3 |
25.7 |
0.53 |
6.96 |
8.0 |
9.7 |
Measurement Method: Four-probe method
"The electrical resistivity... was measured by means of a four lead AC technique at a frequency of 16 Hz." No additional measurement details were noted.
Cautions: Unevaluated Data
"(T
c) is defined as the temperature at which the electrical resistivity reaches (10%)...of its extrapolated normal state value."
Resistivity (normal state) for Y:123; [Y(Pr)-Ba-Cu-O]
x of Prx (formula units) |
y of Oy (formula units) |
Temperature (°C) |
Resistivity (normal state) (mΩ·cm) |
0 |
6.96 |
295 |
0.50 |
0.05 |
6.96 |
295 |
0.70 |
0.10 |
6.97 |
295 |
1.08 |
0.15 |
6.97 |
295 |
1.04 |
0.20 |
6.96 |
295 |
1.17 |
0.30 |
6.97 |
295 |
1.44 |
0.40 |
6.98 |
295 |
1.59 |
0.50 |
6.95 |
295 |
1.99 |
0.53 |
6.96 |
295 |
2.01 |
Measurement Method: Four-probe method
"The electrical resistivity... was measured by means of a four lead AC technique at a frequency of 16 Hz." No additional measurement details were noted.
Cautions: Unevaluated Data