NIST High Temp. Superconducting Materials (HTS) Database:

NIST Standard Reference Database 62

Last Update to Data Content: 1996

DOI: https://doi.org/10.18434/T4KP8J


Bibliographic Information

Title: Ultrasonic Investigations of the Layered Perovskite Ceramic Superconducting Systems
Author(s): H. Yusheng, X. Jiong, J. Sheng, H. Aisheng, and Z. Jincang
Publication: Physica B Volume: 165 Issue: Not Available Year: 1990 Page(s): 1283-1284
Editor(s): Not Available
Publisher: Elsevier Science Publishers B.V.
Language: English
Notes: Not Available
Keywords: Material Specification, Density (mass), Debye Temperature, Elastic Modulus, Shear Modulus, Poisson's Ratio, Bulk Modulus, Sound Velocity

Materials and Properties

La:21; [La(Sr)-Cu-O]
Y:123; [Y-Ba-Cu-O]
Bi:2212; [Bi-Sr-Ca-Cu-O]
Bi:2212; [Bi(Pb)-Sr-Ca-Cu-O]
Bi:2223; [Bi(Pb)-Sr-Ca-Cu-O]
Material Specification for La:21; [La(Sr)-Cu-O] Process: Solid State Reaction
Notes: "The sample studied were prepared by the standard method of solid state reaction." No additional processing details were noted.
Formula: La2-xSrxCuO4
Informal Name: La:21
Chemical Family: La(Sr)-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:

Density (mass) for La:21; [La(Sr)-Cu-O]
Density (g cm-3)
6.22
Measurement Method: Unknown density method

Cautions: Unevaluated Data
No measurement details were noted.
Debye Temperature for La:21; [La(Sr)-Cu-O]
Temperature (K) Debye Temperature (K)
29 381
68 391
86 401
107 408
127 412
171 413
221 412
242 411
260 410
280 411
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 4 of the paper.
Elastic Modulus for La:21; [La(Sr)-Cu-O]
Temperature (K) Elastic Modulus (GPa)
19 109
37 109
56 111
78 116
98 121
126 125
151 126
188 126
227 125
261 125
270 125
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 1 of the paper.
Shear Modulus for La:21; [La(Sr)-Cu-O]
Temperature (K) Shear Modulus (GPa)
16 43.5
34 43.3
53 44.1
75 46.0
88 48.1
114 49.7
142 50.6
185 50.7
233 50.4
261 50.3
270 50.4
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 1 of the paper.
Poisson's Ratio for La:21; [La(Sr)-Cu-O]
Temperature (K) Poisson's Ratio (no unit)
12 0.26
33 0.26
72 0.25
110 0.24
150 0.24
200 0.24
270 0.24
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 1 of the paper.
Bulk Modulus for La:21; [La(Sr)-Cu-O]
Temperature (K) Bulk Modulus (GPa)
25 73.8
44 74.3
66 75.4
82 76.7
98 78.4
119 79.4
144 80.4
185 80.5
222 80.1
240 79.4
259 79.2
271 79.4
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 1 of the paper.
Sound Velocity for La:21; [La(Sr)-Cu-O]
Mode () Sound Velocity (km/s)
Longitudinal 4.834
Shear 2.838
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Material Specification for Y:123; [Y-Ba-Cu-O] Process: Solid State Reaction
Notes: "The sample studied were prepared by the standard method of solid state reaction." No additional processing details were noted.
Formula: YBa2Cu3O7-x
Informal Name: Y:123
Chemical Family: Y-Ba-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:

Density (mass) for Y:123; [Y-Ba-Cu-O]
Density (g cm-3)
5.69
Measurement Method: Unknown density method

Cautions: Unevaluated Data
No measurement details were noted.
Debye Temperature for Y:123; [Y-Ba-Cu-O]
Temperature (K) Debye Temperature (K)
22 488
54 490
102 489
140 488
179 487
190 487
268 482
295 481
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 4 of the paper.
Elastic Modulus for Y:123; [Y-Ba-Cu-O]
Temperature (K) Elastic Modulus (GPa)
11 95.8
87 95.1
150 94.0
200 93.0
252 92.4
288 92.4
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 2 of the paper.
Shear Modulus for Y:123; [Y-Ba-Cu-O]
Temperature (K) Shear Modulus (GPa)
15 40.2
79 39.9
139 39.5
207 38.9
252 38.5
291 38.5
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 2 of the paper.
Poisson's Ratio for Y:123; [Y-Ba-Cu-O]
Temperature (K) Poisson's Ratio (no unit)
20 0.19
100 0.19
215 0.20
290 0.20
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 2 of the paper.
Bulk Modulus for Y:123; [Y-Ba-Cu-O]
Temperature (K) Bulk Modulus (GPa)
8 51.6
17 51.6
36 51.6
39 51.6
42 51.5
70 51.4
94 51.3
107 51.2
119 51.2
125 51.1
134 51.1
215 51.1
234 51.2
243 51.2
252 51.4
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 2 of the paper.
Sound Velocity for Y:123; [Y-Ba-Cu-O]
Mode () Sound Velocity (km/s)
Longitudinal 4.242
Shear 2.599
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Material Specification for Bi:2212; [Bi-Sr-Ca-Cu-O] Process: Solid State Reaction
Notes: "The sample studied were prepared by the standard method of solid state reaction." No additional processing details were noted.
Formula: Bi2Sr2CaCu2O8+x
Informal Name: Bi:2212
Chemical Family: Bi-Sr-Ca-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:

Density (mass) for Bi:2212; [Bi-Sr-Ca-Cu-O]
Density (g cm-3)
5.35
Measurement Method: Unknown density method

Cautions: Unevaluated Data
No measurement details were noted.
Debye Temperature for Bi:2212; [Bi-Sr-Ca-Cu-O]
Temperature (K) Debye Temperature (K)
300 250
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Elastic Modulus for Bi:2212; [Bi-Sr-Ca-Cu-O]
Temperature (K) Elastic Modulus (GPa)
300 38.8
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Shear Modulus for Bi:2212; [Bi-Sr-Ca-Cu-O]
Temperature (K) Shear Modulus (GPa)
300 16.1
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Poisson's Ratio for Bi:2212; [Bi-Sr-Ca-Cu-O]
Temperature (K) Poisson's Ratio (no unit)
300 0.20
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Bulk Modulus for Bi:2212; [Bi-Sr-Ca-Cu-O]
Temperature (K) Bulk Modulus (GPa)
300 21.9
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Sound Velocity for Bi:2212; [Bi-Sr-Ca-Cu-O]
Mode () Sound Velocity (km/s)
Longitudinal 2.846
Shear 1.735
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Material Specification for Bi:2212; [Bi(Pb)-Sr-Ca-Cu-O] Process: Solid State Reaction
Notes: "The sample studied were prepared by the standard method of solid state reaction." No additional processing details were noted.
Formula: Bi2-xPbxSr2CaCu2O8+y
Informal Name: Bi:2212
Chemical Family: Bi(Pb)-Sr-Ca-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:

Density (mass) for Bi:2212; [Bi(Pb)-Sr-Ca-Cu-O]
Density (g cm-3)
5.02
Measurement Method: Unknown density method

Cautions: Unevaluated Data
No measurement details were noted.
Debye Temperature for Bi:2212; [Bi(Pb)-Sr-Ca-Cu-O]
Temperature (K) Debye Temperature (K)
25 275
51 276
104 275
185 273
242 271
283 270
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 4 of the paper.
Elastic Modulus for Bi:2212; [Bi(Pb)-Sr-Ca-Cu-O]
Temperature (K) Elastic Modulus (GPa)
13 39.2
77 39.0
134 38.8
201 38.4
205 38.3
275 37.8
290 37.6
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 3 of the paper.
Shear Modulus for Bi:2212; [Bi(Pb)-Sr-Ca-Cu-O]
Temperature (K) Shear Modulus (GPa)
9 17.1
67 17.0
134 16.8
201 16.6
241 16.4
272 16.2
290 16.1
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 3 of the paper.
Poisson's Ratio for Bi:2212; [Bi(Pb)-Sr-Ca-Cu-O]
Temperature (K) Poisson's Ratio (no unit)
10 0.15
50 0.15
100 0.15
200 0.16
250 0.16
190 0.17
300 0.17
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 3 of the paper.
Bulk Modulus for Bi:2212; [Bi(Pb)-Sr-Ca-Cu-O]
Temperature (K) Bulk Modulus (GPa)
25 18.3
38 18.3
50 18.4
100 18.4
175 18.4
190 18.5
202 18.6
205 18.5
210 18.5
225 18.5
242 18.4
248 18.5
255 18.5
265 18.6
270 18.6
290 18.6
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 3 of the paper.
Sound Velocity for Bi:2212; [Bi(Pb)-Sr-Ca-Cu-O]
Mode () Sound Velocity (km/s)
Longitudinal 2.821
Shear 1.784
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Material Specification for Bi:2223; [Bi(Pb)-Sr-Ca-Cu-O] Process: Solid State Reaction
Notes: "The sample studied were prepared by the standard method of solid state reaction." No additional processing details were noted.
Formula: Bi2-xPbxSr2Ca2Cu3O10+y
Informal Name: Bi:2223
Chemical Family: Bi(Pb)-Sr-Ca-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:

Density (mass) for Bi:2223; [Bi(Pb)-Sr-Ca-Cu-O]
Density (g cm-3)
4.35
Measurement Method: Unknown density method

Cautions: Unevaluated Data
No measurement details were noted.
Debye Temperature for Bi:2223; [Bi(Pb)-Sr-Ca-Cu-O]
Temperature (K) Debye Temperature (K)
25 285
51 286
104 286
185 283
242 281
283 280
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 4 of the paper.
Elastic Modulus for Bi:2223; [Bi(Pb)-Sr-Ca-Cu-O]
Temperature (K) Elastic Modulus (GPa)
13 35.5
77 35.2
134 35.1
201 34.7
205 34.6
275 34.1
290 34.0
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 3 of the paper.
Shear Modulus for Bi:2223; [Bi(Pb)-Sr-Ca-Cu-O]
Temperature (K) Shear Modulus (GPa)
9 15.3
67 15.2
134 15.0
201 14.8
241 14.7
272 14.5
290 14.4
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 3 of the paper.
Poisson's Ratio for Bi:2223; [Bi(Pb)-Sr-Ca-Cu-O]
Temperature (K) Poisson's Ratio (no unit)
10 0.16
50 0.16
100 0.16
150 0.16
200 0.17
250 0.17
290 0.18
300 0.18
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 3 of the paper.
Bulk Modulus for Bi:2223; [Bi(Pb)-Sr-Ca-Cu-O]
Temperature (K) Bulk Modulus (GPa)
25 17.2
50 17.2
100 17.2
150 17.2
175 17.3
200 17.4
225 17.3
250 17.3
270 17.4
290 17.4
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data
Digitized data were obtained from Figure 3 of the paper.
Sound Velocity for Bi:2223; [Bi(Pb)-Sr-Ca-Cu-O]
Mode () Sound Velocity (km/s)
Longitudinal 2.894
Shear 1.813
Measurement Method: Ultrasonic method
The authors cite Y.S. He et al., J. Phys. F, Vol. 17, L243 (1987), and summarize the procedure as follows. "Ultrasonic measurements were carried out by using MATEC 7700 series equipment."

Cautions: Evaluated Data