NIST High Temp. Superconducting Materials (HTS) Database:

NIST Standard Reference Database 62

Last Update to Data Content: 1996

DOI: https://doi.org/10.18434/T4KP8J


Bibliographic Information

Title: Columnar Defects Induced by High Energy Heavy Ions in HTSC. Their Effect on Irreversibility Line and Pinning Properties
Author(s): V. Hardy, J. Provost, D. Groult, Ch. Simon, M. Hervieu, and B. Raveau
Publication: Journal of Alloys and Compounds Volume: 195 Issue: Not Available Year: 1993 Page(s): 395-402
Editor(s): Not Available
Publisher: Elsevier Sequoia
Language: English
Notes: Not Available
Keywords: Material Specification, Irreversibility Field

Materials and Properties

Bi:2212; [Bi-Sr-Ca-Cu-O]
Material Specification for Bi:2212; [Bi-Sr-Ca-Cu-O] Process: Solid State Reaction
Notes: The authors cite V. Hardy et al., Physica C, Vol. 191, 85 (1992), and summarize the procedure as follows. "Single crystals of Bi-2212 type HTSC were prepared... The single crystals were smoothly crushed in alcohol and deposited on a holely carbon coated grid."
Formula: Bi2Sr2CaCu2O8+x
Informal Name: Bi:2212
Chemical Family: Bi-Sr-Ca-Cu-O
Chemical Class: Oxide
Structure Type: Single Crystal
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:

Irreversibility Field for Bi:2212; [Bi-Sr-Ca-Cu-O]
6 GeV-Pb ion Fluence (1010 cm-2) Temperature (K) Irreversibility Field (T)
0 14 5.0
0 15 4.1
0 15 3.1
0 17 2.0
0 20 1.0
0 26 0.3
0 33 0.1
0 55 0.0
1 14 5.0
1 15 4.0
1 15 3.1
1 17 2.0
1 20 1.0
1 25 0.6
1 30 0.4
1 47 0.3
1 70 0.0
5 14 5.0
5 15 4.0
5 19 3.0
5 22 2.0
5 27 1.5
5 40 1.0
5 51 0.7
5 61 0.4
5 62 0.2
5 70 0.0
10 17 5.0
10 20 4.0
10 21 3.0
10 31 2.0
10 42 1.3
10 47 1.0
10 52 0.2
10 60 0.1
10 69 0.0
20 21 5.0
20 31 3.0
20 35 2.5
20 41 2.0
20 48 0.8
20 53 0.2
20 70 0.0
Measurement Method: SQUID magnetometer
"Irradiations were carried out at 300 K. The flux of the ion beam was limited to 2x108 ions cm-2·s-1 in order to avoid warming effects during irradiation. The Bi-2212 single crystals were irradiated along their smallest direction i.e. the c-axis, within an angle resolution of about 5° from it... All magnetic measurements prior to and following heavy ion irradiation were carried out with the DC magnetic field aligned parallel to the c direction... The magnetization hysteresis loops, the field cooled (FC) and zero field cooled (ZFC) magnetizations were recorded with a Quantum Design 5.5 T SQUID magnetometer... The irreversibility lines... were achieved by the determination of the merging point of FC and ZFC curves."

Cautions: Evaluated Data
Digitized data were obtained from Figure 4 of the paper.