Material Specification for Bi:1112; [Bi(Pb,B)-Sr-Ca-Cu-O]
Process: Solid State Reaction
Notes: "The samples were prepared by solid-state reaction using Bi2O3, PbO, SrCO3, CaCO3, CuO and B2O3 as starting reagents. Samples with nominal compositions were mixed for 360 ks by ball-milling, calcined at 1098 K for 36 ks in air, thoroughly reground and then cold-pressed into disk-shape pellets (2 cm in diameter and 1 mm in thickness) at a pressure of 400 MPa. The pellets were then sintered at 1123 K for 720 ks in air."
Formula: Bi0.3B0.5Pb0.2SrCaCuxOy
Informal Name: Bi:1112
Chemical Family: Bi(Pb,B)-Sr-Ca-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:
Crystallography for Bi:1112; [Bi(Pb,B)-Sr-Ca-Cu-O]
Crystal System: | Tetragonal |
Formula Units per Cell: | |
Space Group: |
|
Cell Parameters
x of Cux (formula units) |
Temp
K
|
a
Å
|
b
Å
|
c
Å
|
2.2 |
296 |
5.404 |
-- |
37.32 |
2.4 |
296 |
5.410 |
-- |
37.30 |
2.5 |
296 |
5.409 |
-- |
37.30 |
2.7 |
296 |
5.408 |
-- |
37.29 |
3.0 |
296 |
5.406 |
-- |
37.27 |
Measurement Method: X-ray diffraction
"X-ray powder diffraction analysis at room temperature, using CoKα radiation, was performed to determine the lattice constants..." No additional measurement details were noted.
Cautions: Unevaluated Data
Digitized data were obtained from Figure 4 of the paper.
Critical Temperature for Bi:1112; [Bi(Pb,B)-Sr-Ca-Cu-O]
x of Cux (formula units) |
Tc (onset) () |
Critical Temperature (K) |
2.2 |
115 |
105 |
2.5 |
116 |
107 |
2.7 |
114 |
100 |
Measurement Method: Four-probe method
"The electrical resistivity... (was) measured on bar-shaped specimens cut from the pellets... by standard four-probe... tests." No additional measurement details were noted.
Cautions: Unevaluated Data
Digitized data were obtained from Figure 2 of the paper.
Resistivity (normal state) for Bi:1112; [Bi(Pb,B)-Sr-Ca-Cu-O]
x of Cux (formula units) |
Temperature (K) |
Resistivity (normal state) (mΩ·cm) |
2.2 |
105 |
0.0 |
2.2 |
109 |
2.1 |
2.2 |
114 |
3.9 |
2.2 |
125 |
4.7 |
2.2 |
150 |
5.4 |
2.2 |
200 |
6.4 |
Measurement Method: Four-probe method
"The electrical resistivity... (was) measured on bar-shaped specimens cut from the pellets... by standard four-probe... tests." No additional measurement details were noted.
Cautions: Unevaluated Data
Digitized data were obtained from Figure 6 of the paper.
Flexural Strength for Bi:1112; [Bi(Pb,B)-Sr-Ca-Cu-O]
x of Cux (formula units) |
Flexural Strength (MPa) |
1.8 |
202 |
2.0 |
207 |
2.2 |
201 |
2.4 |
159 |
2.45 |
133 |
2.5 |
59 |
2.7 |
91 |
3.0 |
70 |
Measurement Method: Three-point bend
"The... flexural strength (was) measured on bar-shaped specimens cut from the pellets... by three-point bend tests." No additional measurement details were noted.
Cautions: Unevaluated Data
No stressing rate information was noted.
The authors reported the flexural strength in units of "a.u."
Digitized data were obtained from Figure 1 of the paper.