Material Specification for Y:123; [Y-Ba-Cu-O]
Process: Solid State Reaction
Notes: "High quality YBa2Cu3Ox and Y2Ba4Cu7Oy batches were prepared at high temperature, 980-990 °C and 1010-1020 °C, under (0.1 MPa = 1 bar) and (2.0 MPa = 20 bar) oxygen pressure, respectively. The samples contain grains larger than typically 20 µm. A very small amount of CuO and BaCuO2 (123 samples) or Ba2Cu3Ox (247 samples) was detected in optical and SEM investigations (<0.5% by volume)... to change and homogenize the oxygen concentration, each sample was annealed at a different temperature and oxygen pressure ( (0.1 - 107 Pa) = (10-6-100 bar) ). These long final treatments were followed by quenching into liquid gallium. The oxygen concentration was determined by recording the mass change during the reduction of samples in pure hydrogen flow at 900 °C."
Formula: YBa2Cu3Ox
Informal Name: Y:123
Chemical Family: Y-Ba-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:
Crystallography for Y:123; [Y-Ba-Cu-O]
Crystal System: | Orthorhombic |
Formula Units per Cell: | |
Space Group: |
|
Cell Parameters
x of Ox (formula units) |
Temp
K
|
a
Å
|
b
Å
|
c
Å
|
6.24 |
296 |
3.8586 |
3.8586 |
11.842 |
6.37 |
296 |
3.8447 |
3.8693 |
11.763 |
6.66 |
296 |
3.8299 |
3.8790 |
11.734 |
6.67 |
296 |
3.8315 |
3.8778 |
11.738 |
6.75 |
296 |
3.8238 |
3.8826 |
11.719 |
6.79 |
296 |
3.8232 |
3.8860 |
11.713 |
6.83 |
296 |
3.8255 |
3.8824 |
11.719 |
6.98 |
296 |
3.8175 |
3.8896 |
11.682 |
Measurement Method: X-ray diffraction
The authors cite J.Y. Genoud et al., Physica C, Vol. 192, 137 (1992).
Cautions: Evaluated Data
Critical Temperature for Y:123; [Y-Ba-Cu-O]
x of Ox (formula units) |
Critical Temperature (K) |
6.24 |
0 |
6.37 |
7 |
6.66 |
60.0 |
6.67 |
61.6 |
6.75 |
69.2 |
6.79 |
73.7 |
6.83 |
80.7 |
6.98 |
92.4 |
Measurement Method: Ac susceptibility
"The a.c. susceptibility was measured in a magnetic field of (8 A/m = 0.1 Oe) rms at a frequency of 73 Hz." No additional measurement details were noted.
Cautions: Evaluated Data
Magnetic Susceptibility for Y:123; [Y-Ba-Cu-O]
x of Ox (formula units) |
Temperature (K) |
Magnetic Susceptibility (arbitrary) |
6.98 |
4 |
-1.00 |
6.98 |
33 |
-1.00 |
6.98 |
65 |
-1.00 |
6.98 |
90 |
-0.97 |
6.98 |
92 |
-0.41 |
6.98 |
93 |
-0.04 |
6.98 |
93 |
0.00 |
6.98 |
99 |
0.00 |
6.98 |
100 |
0.00 |
6.83 |
4 |
-1.00 |
6.83 |
23 |
-1.00 |
6.83 |
51 |
-1.00 |
6.83 |
67 |
-1.00 |
6.83 |
75 |
-0.93 |
6.83 |
81 |
-0.47 |
6.83 |
82 |
-0.11 |
6.83 |
84 |
0.00 |
6.83 |
90 |
0.00 |
6.83 |
100 |
0.00 |
6.79 |
4 |
-1.00 |
6.79 |
23 |
-1.00 |
6.79 |
45 |
-1.00 |
6.79 |
62 |
-1.00 |
6.79 |
69 |
-1.00 |
6.79 |
74 |
-0.62 |
6.79 |
74 |
-0.24 |
6.79 |
75 |
-0.05 |
6.79 |
76 |
0.00 |
6.79 |
90 |
0.00 |
6.79 |
100 |
0.00 |
6.75 |
5 |
-1.00 |
6.75 |
27 |
-1.00 |
6.75 |
53 |
-1.00 |
6.75 |
64 |
-1.00 |
6.75 |
69 |
-0.69 |
6.75 |
70 |
-0.28 |
6.75 |
71 |
-0.07 |
6.75 |
73 |
-0.01 |
6.75 |
90 |
0.00 |
6.75 |
100 |
0.00 |
6.67 |
4 |
-1.00 |
6.67 |
23 |
-1.00 |
6.67 |
43 |
-1.00 |
6.67 |
57 |
-0.97 |
6.67 |
61 |
-0.72 |
6.67 |
62 |
-0.28 |
6.67 |
64 |
-0.09 |
6.67 |
69 |
0.00 |
6.67 |
78 |
0.00 |
6.67 |
89 |
0.00 |
6.67 |
99 |
0.00 |
6.67 |
100 |
0.00 |
6.66 |
5 |
-1.00 |
6.66 |
26 |
-1.00 |
6.66 |
51 |
-1.00 |
6.66 |
57 |
-0.87 |
6.66 |
60 |
-0.47 |
6.66 |
64 |
-0.09 |
6.66 |
62 |
0.00 |
6.66 |
75 |
0.00 |
6.66 |
90 |
0.00 |
6.66 |
99 |
0.00 |
6.66 |
100 |
0.00 |
6.37 |
4 |
-0.22 |
6.37 |
6 |
-0.09 |
6.37 |
8 |
-0.03 |
6.37 |
11 |
0.00 |
6.37 |
20 |
0.00 |
6.37 |
30 |
0.00 |
Measurement Method: Ac susceptibility
"The a.c. susceptibility was measured in a magnetic field of (8 A/m = 0.1 Oe) rms at a frequency of 73 Hz." No additional measurement details were noted.
Cautions: Evaluated Data
Digitized data were obtained from Figure 1 of the paper.
Material Specification for Y:247; [Y-Ba-Cu-O]
Process: Solid State Reaction
Notes: "High quality YBa
2Cu
3O
x and Y
2Ba
4Cu
7O
y batches were prepared at high temperature, 980-990 °C and 1010-1020 °C, under (0.1 MPa = 1 bar) and (2.0 MPa = 20 bar) oxygen pressure, respectively. The samples contain grains larger than typically 20 µm. A very small amount of CuO and BaCuO
2 (123 samples) or Ba
2Cu
3O
x (247 samples) was detected in optical and SEM investigations (<0.5% by volume)... to change and homogenize the oxygen concentration, each sample was annealed at a different temperature and oxygen pressure ( (0.1 - 10
7 Pa) = (10
-6-100 bar) ). These long final treatments were followed by quenching into liquid gallium. The oxygen concentration was determined by recording the mass change during the reduction of samples in pure hydrogen flow at 900 °C."
Formula: Y
2Ba
4Cu
7O
x
Informal Name: Y:247
Chemical Family: Y-Ba-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:
Crystallography for Y:247; [Y-Ba-Cu-O]
Crystal System: | Orthorhombic |
Formula Units per Cell: | |
Space Group: |
Cell Parameters
x of Ox (formula units) |
Temp
K
|
a
Å
|
b
Å
|
c
Å
|
14.13 |
296 |
3.8467 |
3.8662 |
50.851 |
14.35 |
296 |
3.8468 |
3.8678 |
50.808 |
14.39 |
296 |
3.8450 |
3.8694 |
50.785 |
14.48 |
296 |
3.8425 |
3.8719 |
50.709 |
14.71 |
296 |
3.8379 |
3.8762 |
50.674 |
14.82 |
296 |
3.8366 |
3.8758 |
50.631 |
14.89 |
296 |
3.8339 |
3.8767 |
50.611 |
15.09 |
296 |
3.8302 |
3.8753 |
50.584 |
Measurement Method: X-ray diffraction
The authors cite J.Y. Genoud et al., Physica C, Vol. 192, 137 (1992).
Cautions: Evaluated Data
Critical Temperature for Y:247; [Y-Ba-Cu-O]
x of Ox (formula units) |
Critical Temperature (K) |
14.13 |
32.2 |
14.35 |
33.7 |
14.39 |
39.5 |
14.48 |
52.9 |
14.71 |
64.6 |
14.82 |
68.2 |
14.89 |
78.1 |
15.09 |
93.1 |
Measurement Method: Ac susceptibility
"The a.c. susceptibility was measured in a magnetic field of (8 A/m = 0.1 Oe) rms at a frequency of 73 Hz." No additional measurement details were noted.
Cautions: Evaluated Data
Magnetic Susceptibility for Y:247; [Y-Ba-Cu-O]
x of Ox (formula units) |
Temperature (K) |
Magnetic Susceptibility (arbitrary) |
14.13 |
5 |
-1.00 |
14.13 |
22 |
-0.95 |
14.13 |
31 |
-0.66 |
14.13 |
34 |
-0.23 |
14.13 |
37 |
0.00 |
14.13 |
59 |
0.00 |
14.13 |
80 |
0.00 |
14.13 |
100 |
0.00 |
14.35 |
5 |
-1.00 |
14.35 |
22 |
-0.95 |
14.35 |
32 |
-0.67 |
14.35 |
36 |
-0.29 |
14.35 |
42 |
0.00 |
14.35 |
59 |
0.00 |
14.35 |
75 |
0.00 |
14.35 |
100 |
0.00 |
14.39 |
21 |
-1.00 |
14.39 |
35 |
-0.91 |
14.39 |
40 |
-0.51 |
14.39 |
42 |
-0.10 |
14.39 |
44 |
0.00 |
14.39 |
60 |
0.00 |
14.39 |
80 |
0.00 |
14.39 |
100 |
0.00 |
14.48 |
21 |
-1.00 |
14.48 |
40 |
-1.00 |
14.48 |
50 |
-0.97 |
14.48 |
53 |
-0.46 |
14.48 |
55 |
-0.13 |
14.48 |
58 |
0.00 |
14.48 |
74 |
0.00 |
14.48 |
100 |
0.00 |
14.71 |
50 |
-1.00 |
14.71 |
61 |
-0.97 |
14.71 |
65 |
-0.54 |
14.71 |
66 |
-0.20 |
14.71 |
68 |
0.00 |
14.71 |
80 |
0.00 |
14.71 |
100 |
0.00 |
14.82 |
57 |
-1.00 |
14.82 |
65 |
-0.98 |
14.82 |
69 |
-0.52 |
14.82 |
70 |
-0.14 |
14.82 |
73 |
0.00 |
14.82 |
84 |
0.00 |
14.82 |
100 |
0.00 |
14.89 |
66 |
-1.00 |
14.89 |
73 |
-1.00 |
14.89 |
79 |
-0.48 |
14.89 |
80 |
-0.14 |
14.89 |
85 |
0.00 |
14.89 |
100 |
0.00 |
15.09 |
74 |
-1.00 |
15.09 |
88 |
-0.97 |
15.09 |
93 |
-0.57 |
15.09 |
94 |
-0.15 |
15.09 |
95 |
0.00 |
15.09 |
100 |
0.00 |
Measurement Method: Ac susceptibility
"The a.c. susceptibility was measured in a magnetic field of (8 A/m = 0.1 Oe) rms at a frequency of 73 Hz." No additional measurement details were noted.
Cautions: Evaluated Data
Digitized data were obtained from Figure 2 of the paper.
|