Material Specification for Y:123; [Y-Ba-Cu-O:Ag]
Process: Solid State Reaction
Notes: The authors cite K. Osamura et al., Supercond. Sci. Technol., Vol. 3, 143 (1990) and summarize the procedure as follows. "The silver sheathed oxide tapes... were prepared by the powder-in-tube method. Firstly, the composite was deformed by various cold-working techniques; grooved rolling (G), swaging (S), drawing (D) and cross-rolling (C). After these workings, the composites were pressed and heat-treated. The principal conditions of heat treatment were at 1113 K for 360 ks for Bi2223 tapes and at 1203 K for 72 ks."
Formula: YBa2Cu3O7-x•yAg
Informal Name: Y:123
Chemical Family: Y-Ba-Cu-O:Ag
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:
Thermal Expansion for Y:123; [Y-Ba-Cu-O:Ag]
Specimen Type () |
Temperature Range (K) |
Thermal Expansion (10-6 K-1) |
bulk |
298 - 773 |
15.2 |
bulk |
298 -1173 |
17.3 |
composite |
298 - 773 |
17.8 |
composite |
298 -1173 |
19.5 |
typical |
298 -1193 |
17.2 |
Measurement Method: Dilatometry
"The thermal expansion of the composite was measured with a dilatometer." No additional measurement details were noted.
Cautions: Evaluated Data
Material Specification for Bi:2223; [Bi(Pb)-Sr-Ca-Cu-O:Ag]
Process: Solid State Reaction
Notes: The authors cite K. Osamura et al., Supercond. Sci. Technol., Vol. 3, 143 (1990) and summarize the procedure as follows. "The silver sheathed oxide tapes... were prepared by the powder-in-tube method. Firstly, the composite was deformed by various cold-working techniques; grooved rolling (G), swaging (S), drawing (D) and cross-rolling (C). After these workings, the composites were pressed and heat-treated. The principal conditions of heat treatment were at 1113 K for 360 ks for Bi2223 tapes and at 1203 K for 72 ks."
Formula: Bi1.6Pb0.4Sr1.6Ca2Cu2.8Ox•yAg
Informal Name: Bi:2223
Chemical Family: Bi(Pb)-Sr-Ca-Cu-O:Ag
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:
Critical Current Density for Bi:2223; [Bi(Pb)-Sr-Ca-Cu-O:Ag]
Cold Working Method () |
Magnetic Field (T) |
Critical Current Density (kA/cm2) |
grooving |
0 |
20 |
grooving |
0.02 |
12 |
grooving |
0.03 |
9.8 |
grooving |
0.10 |
7.5 |
grooving |
0.20 |
6.3 |
grooving |
0.30 |
5.3 |
grooving |
0.40 |
4.7 |
grooving |
0.50 |
4.2 |
swaging |
0 |
6.0 |
swaging |
0.01 |
2.9 |
swaging |
0.03 |
2.2 |
swaging |
0.07 |
1.9 |
swaging |
0.20 |
1.3 |
swaging |
0.40 |
0.97 |
swaging |
0.50 |
0.86 |
Measurement Method: Transport current
"The transport critical current measurements have been performed under external magnetic field at 77 K with criterion of 1 µV/cm." No additional measurement details were noted.
Cautions: Evaluated Data
Digitized data were obtained from Figure 5 of the paper.
Thermal Expansion for Bi:2223; [Bi(Pb)-Sr-Ca-Cu-O:Ag]
Specimen Type () |
Temperature Range (K) |
Thermal Expansion (10-6 K-1) |
bulk |
298 - 723 |
12.4 |
bulk |
298 -1073 |
13.3 |
composite |
298 - 723 |
11.3 |
composite |
298 -1073 |
13.5 |
composite |
298 - 723 |
11.6 |
composite |
298 -1023 |
14.5 |
typical |
298 -1113 |
13.6 |
Measurement Method: Dilatometry
"The thermal expansion of the composite was measured with a dilatometer." No additional measurement details were noted.
Cautions: Evaluated Data