NIST High Temp. Superconducting Materials (HTS) Database:

NIST Standard Reference Database 62

Last Update to Data Content: 1996

DOI: https://doi.org/10.18434/T4KP8J


Bibliographic Information

Title: Irreversibility Line and Critical Current Densities of '1223' Cuprate TlBa2Ca2Cu3O9: A Single Crystal Study
Author(s): A. Wahl, V. Hardy, A. Maignan, C. Martin, and B. Raveau
Publication: Cryogenics Volume: 34 Issue: 11 Year: 1994 Page(s): 941-945
Editor(s): Not Available
Publisher: Butterworth-Heinemann Ltd.
Language: English
Notes: Not Available
Keywords: Material Specification, Critical Temperature, Critical Current Density, Irreversibility Field

Materials and Properties

Tl:1223; [Tl-Ba-Ca-Cu-O]
Material Specification for Tl:1223; [Tl-Ba-Ca-Cu-O] Process: Melt Processed
Notes: The authors cite A. Maignan et al., Physica C, Vol. 219, 407 (1994), and summarize the procedure as follows. "Single crystals have been grown from melts of BaCuO2:CaO:Tl2O3 in the ratio 2:2:1/2. ... One of these crystals, with dimensions 0.81 x 0.48 x 0.13 mm3, was retained for the magnetic study."
Formula: TlBa2Ca2Cu3O9
Informal Name: Tl:1223
Chemical Family: Tl-Ba-Ca-Cu-O
Chemical Class: Oxide
Structure Type: Single Crystal
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:

Critical Temperature for Tl:1223; [Tl-Ba-Ca-Cu-O]
Critical Temperature (K)
114
Measurement Method: SQUID magnetometer
"...Jc values and the irreversibility line location derived from magnetic hysteresis loops are presented... The magnetic measurements were carried out by means of a 5.5 T SQUID magnetometer in the configuration H//c. ... The critical current densities have been evaluated from the hysteresis loops using an extended Bean model for rectangular shaped samples. ... For temperatures not too close to Tc ( ≤ 105 K), the determination of H (T) using the closing points of the hysteresis loops is quite definite."

Cautions: Evaluated Data
Critical Current Density for Tl:1223; [Tl-Ba-Ca-Cu-O]
Temperature (K) Magnetic Field (kA/m) Critical Current Density (kA/cm2)
30 850 720
30 1400 600
30 2400 430
40 83 310
40 230 260
40 490 290
40 1000 280
40 2000 150
40 3800 50
50 120 140
50 230 160
50 490 180
50 1000 110
50 1800 38
50 2600 15
50 4000 3.6
60 47 80
60 160 89
60 400 100
60 1000 33
60 1600 7.0
60 2300 1.5
60 2700 0.23
60 3500 0.037
70 39 32
70 170 48
70 330 47
70 650 16
70 990 3.3
70 1300 0.38
70 1600 0.051
80 24 15
80 39 13
80 76 15
80 150 22
80 260 19
80 400 8.6
80 500 2.5
80 680 0.62
80 810 0.18
90 15 6.2
90 32 3.8
90 67 5.8
90 120 9.0
90 200 4.1
90 290 1.2
90 460 0.034
100 6 4.0
100 16 1.3
100 49 0.80
100 59 0.58
100 110 0.57
100 140 0.089
100 160 0.022
100 160 0.140
100 180 0.0048
100 180 0.041
100 190 0.019
100 210 0.0088
Measurement Method: SQUID magnetometer
"...Jc values and the irreversibility line location derived from magnetic hysteresis loops are presented... The magnetic measurements were carried out by means of a 5.5 T SQUID magnetometer in the configuration H//c. ... The critical current densities have been evaluated from the hysteresis loops using an extended Bean model for rectangular shaped samples. ... For temperatures not too close to Tc ( ≤ 105 K), the determination of H (T) using the closing points of the hysteresis loops is quite definite."

Cautions: Evaluated Data
Digitized data were obtained from Figure 4 of the paper.
Irreversibility Field for Tl:1223; [Tl-Ba-Ca-Cu-O]
Temperature (K) Irreversibility Field (T)
60 4.0
70 2.0
80 1.1
90 0.56
100 0.27
105 0.12
107 0.087
Measurement Method: SQUID magnetometer
"...Jc values and the irreversibility line location derived from magnetic hysteresis loops are presented... The magnetic measurements were carried out by means of a 5.5 T SQUID magnetometer in the configuration H//c. ... The critical current densities have been evaluated from the hysteresis loops using an extended Bean model for rectangular shaped samples. ... For temperatures not too close to Tc ( ≤ 105 K), the determination of H (T) using the closing points of the hysteresis loops is quite definite."

Cautions: Evaluated Data
Digitized data were obtained from Figure 6 of the paper.