Title: Superconductivity in RNi2B2C (R = rare earth) Compounds
Author(s): C.V. Tomy, L.J. Chang, G. Balakrishnan, and D.McK. Paul
Publication: Physica C Volume: 235 Issue: Not Available Year: 1994 Page(s): 2551-2552
Editor(s): Not Available
Publisher: Elsevier Science Publishers B.V.
Language: English
Notes: Vol. 235-240, multiple volume issue
Keywords: Material Specification, Critical Temperature

Materials and Properties

[Y(Dy)-Ni-B-C]
[Y(Sm)-Ni-B-C]
[Ho(Er)-Ni-B-C]
Material Specification for ; [Y(Dy)-Ni-B-C] Process: Melt Processed
Notes: "Samples were prepared by the standard arc-melting technique. The constituent element, R(99.9%), Ni(99.99%), B(99.7%) and the graphite flakes, were melted in a water cooled copper hearth in flowing argon atmosphere. Weight losses if any, were compensated for during the melting. The resulting buttons were turned over and melted several times in order to ensure homogeneity. These buttons were then wrapped in tantalum foil and annealed in evacuated and sealed quartz tubes at 975-1050 °C for 12-16 h."
Formula: Y1-xDyxN2B2C
Informal Name:
Chemical Family: Y(Dy)-Ni-B-C
Chemical Class: Carbide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:

Critical Temperature for ; [Y(Dy)-Ni-B-C]
x (formula units) Critical Temperature (K)
0.0 15.7
0.1 13.2
0.2 12.7
0.3 10.4
0.5 7.0
0.7 4.0
0.8 3.7
Measurement Method: Four-probe method
"Resistance measurements (1.2-300 K) were carried out on bar shaped samples by the standard four probe method." No additional measurement details were noted.

Cautions: Unevaluated Data
Digitized data were obtained from Figure 1 of the paper.
Material Specification for ; [Y(Sm)-Ni-B-C] Process: Melt Processed
Notes: "Samples were prepared by the standard arc-melting technique. The constituent element, R(99.9%), Ni(99.99%), B(99.7%) and the graphite flakes, were melted in a water cooled copper hearth in flowing argon atmosphere. Weight losses if any, were compensated for during the melting. The resulting buttons were turned over and melted several times in order to ensure homogeneity. These buttons were then wrapped in tantalum foil and annealed in evacuated and sealed quartz tubes at 975-1050 °C for 12-16 h."
Formula: Y1-xSmxN2B2C
Informal Name:
Chemical Family: Y(Sm)-Ni-B-C
Chemical Class: Carbide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:

Critical Temperature for ; [Y(Sm)-Ni-B-C]
x (formula units) Critical Temperature (K)
0.1 9.3
0.2 7.9
0.3 3.6
0.4 0.0
Measurement Method: Four-probe method
"Resistance measurements (1.2-300 K) were carried out on bar shaped samples by the standard four probe method." No additional measurement details were noted.

Cautions: Unevaluated Data
Digitized data were obtained from Figure 1 of the paper.
Material Specification for ; [Ho(Er)-Ni-B-C] Process: Melt Processed
Notes: "Samples were prepared by the standard arc-melting technique. The constituent element, R(99.9%), Ni(99.99%), B(99.7%) and the graphite flakes, were melted in a water cooled copper hearth in flowing argon atmosphere. Weight losses if any, were compensated for during the melting. The resulting buttons were turned over and melted several times in order to ensure homogeneity. These buttons were then wrapped in tantalum foil and annealed in evacuated and sealed quartz tubes at 975-1050 °C for 12-16 h."
Formula: Ho1-xErxNi2B2C
Informal Name:
Chemical Family: Ho(Er)-Ni-B-C
Chemical Class: Carbide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:

Critical Temperature for ; [Ho(Er)-Ni-B-C]
x (formula units) Critical Temperature (K)
0.0 6.6
0.2 7.7
0.4 9.0
1.0 9.4
Measurement Method: Four-probe method
"Resistance measurements (1.2-300 K) were carried out on bar shaped samples by the standard four probe method." No additional measurement details were noted.

Cautions: Unevaluated Data
Digitized data were obtained from Figure 3 of the paper.