Material Specification for ; [Y-Ni-B-C]
Process: Melt Processed
Notes: "Briefly, an annealed, single-phase button of arc-melted RENi2B2C is heated in flowing argon to 1490 °C with an equal mass of Ni2B, which acts as a flux. Cooling to 1200 °C at 10 °C/h, followed by furnace cooling to room temperature, produces single crystals that grow into the flux."
Formula: YNi2B2C
Informal Name:
Chemical Family: Y-Ni-B-C
Chemical Class: Carbide
Structure Type: Single Crystal
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:
Specific Heat for ; [Y-Ni-B-C]
Magnetic Field (T) |
Temperature (K) |
Specific Heat (J kg-1 K-1) |
0 |
2 |
0.01 |
0 |
8 |
0.68 |
0 |
11 |
2.06 |
0 |
13 |
3.31 |
0 |
14 |
4.25 |
0 |
15 |
2.95 |
0 |
17 |
3.83 |
0 |
18 |
4.52 |
0 |
19 |
5.28 |
0 |
20 |
5.59 |
5 |
1 |
0.11 |
5 |
8 |
0.92 |
5 |
13 |
2.02 |
5 |
15 |
2.99 |
5 |
18 |
4.40 |
5 |
20 |
5.78 |
Measurement Method: Specific heat methods
"Specific heat above 1.5 K was measured using a standard decay method on at most four crystals with a total mass of 30-40 mg; whereas, lower temperature measurements were made using a semi-adiabatic technique." No additional measurement details were noted.
Cautions: Unevaluated Data
Digitized data were obtained from Figure 1 of the paper.
Material Specification for ; [Tm-Ni-B-C]
Process: Melt Processed
Notes: "Briefly, an annealed, single-phase button of arc-melted RENi2B2C is heated in flowing argon to 1490 °C with an equal mass of Ni2B, which acts as a flux. Cooling to 1200 °C at 10 °C/h, followed by furnace cooling to room temperature, produces single crystals that grow into the flux."
Formula: TmNi2B2C
Informal Name:
Chemical Family: Tm-Ni-B-C
Chemical Class: Carbide
Structure Type: Single Crystal
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:
Specific Heat for ; [Tm-Ni-B-C]
Magnetic Field (T) |
Temperature (K) |
Specific Heat (J kg-1 K-1) |
0 |
0.11 |
2.00 |
0 |
0.19 |
1.75 |
0 |
0.26 |
1.74 |
0 |
0.50 |
3.93 |
0 |
0.74 |
6.12 |
0 |
0.97 |
9.21 |
0 |
1.19 |
13.66 |
0 |
1.33 |
16.56 |
0 |
1.47 |
20.57 |
0 |
1.54 |
18.53 |
0 |
1.55 |
16.27 |
0 |
1.57 |
9.51 |
0 |
1.63 |
4.99 |
0 |
1.64 |
4.53 |
0 |
1.71 |
4.29 |
0 |
1.74 |
4.06 |
0 |
4.5 |
1.91 |
0 |
6.7 |
4.53 |
0 |
8.7 |
8.63 |
0 |
10.0 |
10.93 |
0 |
10.7 |
11.88 |
0 |
11.2 |
11.95 |
0 |
13.6 |
15.37 |
0 |
16.4 |
18.08 |
0 |
18.6 |
20.4 |
0 |
20.9 |
22.47 |
Measurement Method: Specific heat methods
"Specific heat above 1.5 K was measured using a standard decay method on at most four crystals with a total mass of 30-40 mg; whereas, lower temperature measurements were made using a semi-adiabatic technique." No additional measurement details were noted.
Cautions: Unevaluated Data
Digitized data were obtained from Figures 3 and 4 of the paper.