Material Specification for Bi:2212; [Bi-Sr-Ca-Cu-O]
Process: Solid State Reaction
Notes: "Polycrystalline samples...were prepared by common powder metallurgical method." No additional processing details were noted.
Formula: Bi2Sr2CaCu2O8+x
Informal Name: Bi:2212
Chemical Family: Bi-Sr-Ca-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:
Critical Temperature for Bi:2212; [Bi-Sr-Ca-Cu-O]
Critical Temperature (K) |
85 |
Measurement Method: Unknown Tc method
No measurement details were noted.
Cautions: Unevaluated Data
Energy Gap(2 delta) for Bi:2212; [Bi-Sr-Ca-Cu-O]
Measurement Method: Tunneling spectroscopy
"The tunneling spectroscopy measurements indicate that there is an energy region around the Fermi energy in high-T
c superconductors within which the density of states is sharply reduced. This region is called "energy gap". ... The point-contact (PC) technique has been used to make the tunnel junctions using a silver needle at 4.2K." No additional measurement details were noted.
Cautions: Unevaluated Data
Material Specification for Bi:2223; [Bi-Sr-Ca-Cu-O]
Process: Solid State Reaction
Notes: "Polycrystalline samples...were prepared by common powder metallurgical method." No additional processing details were noted.
Formula: Bi1.8Pb0.3Sr2Ca2Cu3O10+x
Informal Name: Bi:2223
Chemical Family: Bi-Sr-Ca-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:
Critical Temperature for Bi:2223; [Bi-Sr-Ca-Cu-O]
Critical Temperature (K) |
108 |
Measurement Method: Unknown Tc method
No measurement details were noted.
Cautions: Unevaluated Data
Energy Gap(2 delta) for Bi:2223; [Bi-Sr-Ca-Cu-O]
Measurement Method: Tunneling spectroscopy
"The tunneling spectroscopy measurements indicate that there is an energy region around the Fermi energy in high-T
c superconductors within which the density of states is sharply reduced. This region is called "energy gap". ... The point-contact (PC) technique has been used to make the tunnel junctions using a silver needle at 4.2K." No additional measurement details were noted.
Cautions: Unevaluated Data