NIST High Temp. Superconducting Materials (HTS) Database:

NIST Standard Reference Database 62

Last Update to Data Content: 1996

DOI: https://doi.org/10.18434/T4KP8J


Bibliographic Information

Title: Measurement of critical temperature (Tc)
Author(s): Not Available
Publication: STA Project Data Volume: Not Available Issue: Not Available Year: 1991 Page(s): Not Available
Editor(s): Not Available
Publisher: Science and Technology Agency of Japan
Language: Japanese
Notes: STA sheet number: 15,16
Keywords: Material Specification, Critical Temperature, Resistivity (normal state)

Materials and Properties

Bi:2212; [Bi-Sr-Ca-Cu-O]
Material Specification for Bi:2212; [Bi-Sr-Ca-Cu-O] Process:
Notes:
Formula: Bi2Sr2CaCu2O8
Informal Name: Bi:2212
Chemical Family: Bi-Sr-Ca-Cu-O
Chemical Class: Oxide
Structure Type:
Manufacturer:
Commercial Name:
Production Date:
Lot Number: BHKBL8
Production Form:
Critical Temperature for Bi:2212; [Bi-Sr-Ca-Cu-O]
Critical Temperature (K)
51
Measurement Method: Resistivity
Test facility: Chyuo Kenkyu-syo, Mitsubishi Material Location: Rm. 214, Main Bldg. Start date: 27-Mar-87 Environment temperature (avg): 22 °C Environment humidity (avg): 40 % Remark on specimen: cutting a specimen with 2 mm width from obtained sample, winding a copper wire and pressing it on the ends of the specimen by using Ag paste and solder, setting the specimen on test equipment Cooling rate: 3 K/min Test environment: 0.1MPa (1 atm) He gas Current: 5 mA Definition of Tc: defining the temperature at which voltage became 1 µV/cm as Tc(end)

Cautions: Research Data
Resistivity (normal state) for Bi:2212; [Bi-Sr-Ca-Cu-O]
Temperature (K) Resistivity (normal state) (mΩ·cm)
75 0.931
74 0.923
73 0.910
72 0.897
71 0.872
70 0.855
69 0.828
68 0.780
67 0.717
66 0.646
65 0.562
64 0.480
63 0.417
62 0.364
61 0.326
60 0.295
59 0.257
58 0.223
57 0.192
56 0.157
55 0.120
54 0.0887
53 0.0555
52 0.0347
51 0.0167
50 0.00978
49 0.00532
Measurement Method: Resistivity
Test facility: Chyuo Kenkyu-syo, Mitsubishi Material Location: Rm. 214, Main Bldg. Start date: 27-Mar-87 Environment temperature (avg): 22 °C Environment humidity (avg): 40 % Remark on specimen: cutting a specimen with 2 mm width from obtained sample, winding a copper wire and pressing it on the ends of the specimen by using Ag paste and solder, setting the specimen on test equipment Cooling rate: 3 K/min Test environment: 0.1MPa (1 atm) He gas Current: 5 mA Definition of Tc: defining the temperature at which voltage became 1 µV/cm as Tc(end)

Cautions: Research Data