NIST High Temp. Superconducting Materials (HTS) Database:

NIST Standard Reference Database 62

Last Update to Data Content: 1996

DOI: https://doi.org/10.18434/T4KP8J


Bibliographic Information

Title: Measurement of critical temperature (Tc)
Author(s): Not Available
Publication: STA Project Data Volume: Not Available Issue: Not Available Year: 1991 Page(s): Not Available
Editor(s): Not Available
Publisher: Science and Technology Agency of Japan
Language: Japanese
Notes: STA sheet number: 17,18
Keywords: Material Specification, Critical Temperature, Resistivity (normal state)

Materials and Properties

Bi:2212; [Bi-Sr-Ca-Cu-O]
Material Specification for Bi:2212; [Bi-Sr-Ca-Cu-O] Process:
Notes:
Formula: Bi2Sr2CaCu2O8
Informal Name: Bi:2212
Chemical Family: Bi-Sr-Ca-Cu-O
Chemical Class: Oxide
Structure Type:
Manufacturer:
Commercial Name:
Production Date:
Lot Number: BDKBL8
Production Form:
Critical Temperature for Bi:2212; [Bi-Sr-Ca-Cu-O]
Critical Temperature (K)
81
Measurement Method: Resistivity
Test facility: Chyuo Kenkyu-syo, Mitsubishi Material Location: Rm. 214, Main Bldg. Start date: 4-Mar-87 Environment temperature (avg): 22 °C Environment humidity (avg): 40 % Remark on specimen: cutting a specimen with 2 mm width from the obtained sample, winding a copper wire and pressing it on the ends of the specimen by using Ag paste and solder, setting the specimen on test equipment Cooling rate: 3 K/min Test environment: 0.1 MPa (1 atm) He gas Current: 5 mA Definition of Tc: defining the temperature at which voltage became 1 µV/cm as Tc(end)

Cautions: Research Data
Resistivity (normal state) for Bi:2212; [Bi-Sr-Ca-Cu-O]
Temperature (K) Resistivity (normal state) (mΩ·cm)
100 0.0625
99 0.0617
98 0.0609
97 0.0594
96 0.0589
95 0.0578
94 0.0572
93 0.0563
92 0.0550
91 0.0538
90 0.0524
89 0.0507
88 0.0488
87 0.0465
86 0.0426
85 0.0377
84 0.0301
83 0.0146
82 0.00419
81 0.00113
80 0.00039
79 0.000647
Measurement Method: Resistivity
Test facility: Chyuo Kenkyu-syo, Mitsubishi Material Location: Rm. 214, Main Bldg. Start date: 4-Mar-87 Environment temperature (avg): 22 °C Environment humidity (avg): 40 % Remark on specimen: cutting a specimen with 2 mm width from the obtained sample, winding a copper wire and pressing it on the ends of the specimen by using Ag paste and solder, setting the specimen on test equipment Cooling rate: 3 K/min Test environment: 0.1 MPa (1 atm) He gas Current: 5 mA Definition of Tc: defining the temperature at which voltage became 1 µV/cm as Tc(end)

Cautions: Research Data