Title: Measurement of critical temperature (Tc)
Author(s): Not Available
Publication: STA Project Data Volume: Not Available Issue: Not Available Year: 1991 Page(s): Not Available
Editor(s): Not Available
Publisher: Science and Technology Agency of Japan
Language: Japanese
Notes: STA sheet number: 19,20
Keywords: Material Specification, Critical Temperature, Resistivity (normal state)

Materials and Properties

Bi:2212; [Bi-Sr-Ca-Cu-O]
Material Specification for Bi:2212; [Bi-Sr-Ca-Cu-O] Process:
Notes:
Formula: Bi2Sr2CaCu2O8
Informal Name: Bi:2212
Chemical Family: Bi-Sr-Ca-Cu-O
Chemical Class: Oxide
Structure Type:
Manufacturer:
Commercial Name:
Production Date:
Lot Number: BSDBL8
Production Form:
Critical Temperature for Bi:2212; [Bi-Sr-Ca-Cu-O]
Critical Temperature (K)
59
Measurement Method: Resistivity
Test facility: Chyuo Kenkyu-syo, Mitsubishi Material Location: Rm. 214, Main Bldg. Start date: 12-May-87 Environment temperature (avg): 22 °C Environment humidity (avg): 40 % Remark on specimen: cutting a specimen with 2 mm width from the obtained sample, winding a copper wire and pressing it on the ends of the specimen by using Ag paste and solder, setting the specimen on test equipment Cooling rate: 3 K/min Test environment: 0.1 MPa (1 atm) He gas Current: 5 mA Definition of Tc: defining the temperature at which voltage became 1 µV/cm as Tc(end)

Cautions: Research Data
Resistivity (normal state) for Bi:2212; [Bi-Sr-Ca-Cu-O]
Temperature (K) Resistivity (normal state) (mΩ·cm)
80 0.0253
79 0.0249
78 0.0248
77 0.0246
76 0.0241
75 0.0234
74 0.0233
73 0.0225
72 0.0221
71 0.0211
70 0.0203
69 0.0185
68 0.0164
67 0.0138
66 0.0109
65 0.00849
64 0.00699
63 0.00529
62 0.00462
61 0.00381
60 0.00292
59 0.00181
58 0.00089
57 0.000481
Measurement Method: Resistivity
Test facility: Chyuo Kenkyu-syo, Mitsubishi Material Location: Rm. 214, Main Bldg. Start date: 12-May-87 Environment temperature (avg): 22 °C Environment humidity (avg): 40 % Remark on specimen: cutting a specimen with 2 mm width from the obtained sample, winding a copper wire and pressing it on the ends of the specimen by using Ag paste and solder, setting the specimen on test equipment Cooling rate: 3 K/min Test environment: 0.1 MPa (1 atm) He gas Current: 5 mA Definition of Tc: defining the temperature at which voltage became 1 µV/cm as Tc(end)

Cautions: Research Data