NIST High Temp. Superconducting Materials (HTS) Database:

NIST Standard Reference Database 62

Last Update to Data Content: 1996

DOI: https://doi.org/10.18434/T4KP8J


Bibliographic Information

Title: Measurement of critical temperature (Tc)
Author(s): Not Available
Publication: STA Project Data Volume: Not Available Issue: Not Available Year: 1991 Page(s): Not Available
Editor(s): Not Available
Publisher: Science and Technology Agency of Japan
Language: Japanese
Notes: STA sheet number: 27,28
Keywords: Material Specification, Critical Temperature, Resistivity (normal state)

Materials and Properties

Bi:2212; [Bi-Sr-Ca-Cu-O]
Material Specification for Bi:2212; [Bi-Sr-Ca-Cu-O] Process:
Notes:
Formula: Bi2Sr2CaCu2O8
Informal Name: Bi:2212
Chemical Family: Bi-Sr-Ca-Cu-O
Chemical Class: Oxide
Structure Type:
Manufacturer:
Commercial Name:
Production Date:
Lot Number: BSDBL9
Production Form:
Critical Temperature for Bi:2212; [Bi-Sr-Ca-Cu-O]
Critical Temperature (K)
70
Measurement Method: Resistivity
Test facility: Chyuo Kenkyu-syo, Mitsubishi Material Location: Rm. 214, Main Bldg. Start date: 12-May-87 Environment temperature (avg): 22 °C Environment humidity (avg): 40 % Remark on specimen: cutting a specimen with 2 mm width from the obtained sample, winding a copper wire and pressing it on the ends of the specimen by using Ag paste and solder, setting the specimen on test equipment Cooling rate: 3 K/min Test environment: 0.1 MPa (1 atm) He gas Current: 5 mA Definition of Tc: defining the temperature at which voltage became 1 µV/cm as Tc(end)

Cautions: Research Data
Resistivity (normal state) for Bi:2212; [Bi-Sr-Ca-Cu-O]
Temperature (K) Resistivity (normal state) (mΩ·cm)
100 0.208
99 0.207
98 0.205
97 0.203
96 0.201
95 0.199
94 0.196
93 0.192
92 0.187
91 0.181
90 0.175
89 0.166
88 0.157
87 0.149
86 0.139
85 0.131
84 0.123
83 0.113
82 0.105
81 0.096
80 0.086
79 0.077
78 0.0687
77 0.0589
76 0.0479
75 0.0367
74 0.0262
73 0.0174
72 0.0102
71 0.00499
70 0.00217
69 0.000788
68 0.00045
Measurement Method: Resistivity
Test facility: Chyuo Kenkyu-syo, Mitsubishi Material Location: Rm. 214, Main Bldg. Start date: 12-May-87 Environment temperature (avg): 22 °C Environment humidity (avg): 40 % Remark on specimen: cutting a specimen with 2 mm width from the obtained sample, winding a copper wire and pressing it on the ends of the specimen by using Ag paste and solder, setting the specimen on test equipment Cooling rate: 3 K/min Test environment: 0.1 MPa (1 atm) He gas Current: 5 mA Definition of Tc: defining the temperature at which voltage became 1 µV/cm as Tc(end)