Title: Measurement of critical temperature (Tc)
Author(s): Not Available
Publication: STA Project Data Volume: Not Available Issue: Not Available Year: 1991 Page(s): Not Available
Editor(s): Not Available
Publisher: Science and Technology Agency of Japan
Language: Japanese
Notes: STA sheet number: 35,36
Keywords: Material Specification, Critical Temperature, Resistivity (normal state)

Materials and Properties

Bi:2223; [Bi-Sr-Ca-Cu-O]
Material Specification for Bi:2223; [Bi-Sr-Ca-Cu-O] Process:
Notes:
Formula: Bi2Sr2Ca2Cu3O10
Informal Name: Bi:2223
Chemical Family: Bi-Sr-Ca-Cu-O
Chemical Class: Oxide
Structure Type:
Manufacturer:
Commercial Name:
Production Date:
Lot Number: BSDBH
Production Form:

Critical Temperature for Bi:2223; [Bi-Sr-Ca-Cu-O]
Critical Temperature (K)
94
Measurement Method: Resistivity
Test facility: Chyuo Kenkyu-syo, Mitsubishi Material Location: Rm. 214, Main Bldg. Start date: 12-May-87 Environment temperature (avg): 22 °C Environment humidity (avg): 40 % Remark on specimen: cutting a specimen with 2 mm width from the obtained sample, winding a copper wire and pressing it on the ends of the specimen by using Ag paste and solder, setting the specimen on test equipment Cooling rate: 3 K/min Test environment: 0.1 MPa (1 atm) He gas Current: 5 mA Definition of Tc: defining the temperature at which voltage became 1 µV/cm as Tc(end)

Cautions: Research Data
Resistivity (normal state) for Bi:2223; [Bi-Sr-Ca-Cu-O]
Temperature (K) Resistivity (normal state) (mΩ·cm)
110 0.125
109 0.122
108 0.120
107 0.117
106 0.112
105 0.105
104 0.0965
103 0.0839
102 0.0681
101 0.0606
100 0.0557
99 0.0504
98 0.0421
97 0.0314
96 0.0200
95 0.00891
94 0.00266
93 0.000549
92 0.000335
Measurement Method: Resistivity
Test facility: Chyuo Kenkyu-syo, Mitsubishi Material Location: Rm. 214, Main Bldg. Start date: 12-May-87 Environment temperature (avg): 22 °C Environment humidity (avg): 40 % Remark on specimen: cutting a specimen with 2 mm width from the obtained sample, winding a copper wire and pressing it on the ends of the specimen by using Ag paste and solder, setting the specimen on test equipment Cooling rate: 3 K/min Test environment: 0.1 MPa (1 atm) He gas Current: 5 mA Definition of Tc: defining the temperature at which voltage became 1 µV/cm as Tc(end)

Cautions: Research Data