NIST High Temp. Superconducting Materials (HTS) Database:

NIST Standard Reference Database 62

Last Update to Data Content: 1996

DOI: https://doi.org/10.18434/T4KP8J


Bibliographic Information

Title: Measurement of critical temperature (Tc)
Author(s): Not Available
Publication: STA Project Data Volume: Not Available Issue: Not Available Year: 1991 Page(s): Not Available
Editor(s): Not Available
Publisher: Science and Technology Agency of Japan
Language: Japanese
Notes: STA sheet number: 68,69
Keywords: Material Specification, Critical Temperature, Resistivity (normal state)

Materials and Properties

Bi:2212; [Bi-Sr-Ca-Cu-O]
Material Specification for Bi:2212; [Bi-Sr-Ca-Cu-O] Process:
Notes:
Formula: Bi2Sr2CaCu2O8
Informal Name: Bi:2212
Chemical Family: Bi-Sr-Ca-Cu-O
Chemical Class: Oxide
Structure Type:
Manufacturer:
Commercial Name:
Production Date:
Lot Number: TFJBL
Production Form: Wire
Critical Temperature for Bi:2212; [Bi-Sr-Ca-Cu-O]
Critical Temperature (K)
81
Measurement Method: Resistivity
Test facility: Chyuo Kenkyu-syo, Mitsubishi Material Location: R214 Lab., Chyuo Kenkyu-syo Start date: 24-Mar-87 Environment temperature (avg): 20 °C Environment humidity (avg): 42 % Size of Ag sheathed wire: 0.075 mm x 4.4 mm x 6.0l mm Definition of Tc: defining the temperature at which voltage became 1 µV/cm as Tc(end) Cooling rate: 3 K/min Test environment: 0.1 MPa (1 atm) He gas

Cautions: Research Data
Resistivity (normal state) for Bi:2212; [Bi-Sr-Ca-Cu-O]
Temperature (K) Resistivity (normal state) (mΩ·cm)
95 0.000577
94 0.000555
93 0.000539
92 0.000546
91 0.000523
90 0.000529
89 0.000508
88 0.0005
87 0.000475
86 0.000432
85 0.000355
84 0.000284
83 0.000207
82 0.000127
81 0.000062
80 0.000028
79 0.000016
78 0.000018
77 0.000014
76 0.000014
75 0.000018
Measurement Method: Resistivity
Test facility: Chyuo Kenkyu-syo, Mitsubishi Material Location: R214 Lab., Chyuo Kenkyu-syo Start date: 24-Mar-87 Environment temperature (avg): 20 °C Environment humidity (avg): 42 % Size of Ag sheathed wire: 0.075 mm x 4.4 mm x 6.0l mm Definition of Tc: defining the temperature at which voltage became 1 µV/cm as Tc(end) Cooling rate: 3 K/min Test environment: 0.1 MPa (1 atm) He gas

Cautions: Research Data