NIST High Temp. Superconducting Materials (HTS) Database:

NIST Standard Reference Database 62

Last Update to Data Content: 1996

DOI: https://doi.org/10.18434/T4KP8J


Bibliographic Information

Title: Measurement of critical temperature (Tc)
Author(s): Not Available
Publication: STA Project Data Volume: Not Available Issue: Not Available Year: 1991 Page(s): Not Available
Editor(s): Not Available
Publisher: Science and Technology Agency of Japan
Language: Japanese
Notes: STA sheet number: 88,89
Keywords: Material Specification, Critical Temperature, Resistivity (normal state)

Materials and Properties

Bi:2223; [Bi-Sr-Ca-Cu-O]
Material Specification for Bi:2223; [Bi-Sr-Ca-Cu-O] Process:
Notes:
Formula: Bi2Sr2Ca2Cu3O10
Informal Name: Bi:2223
Chemical Family: Bi-Sr-Ca-Cu-O
Chemical Class: Oxide
Structure Type:
Manufacturer:
Commercial Name:
Production Date:
Lot Number: ADKBHM3
Production Form:

Critical Temperature for Bi:2223; [Bi-Sr-Ca-Cu-O]
Critical Temperature (K)
92
Measurement Method: Resistivity
Test facility: Chyuo Kenkyu-syo, Mitsubishi Material Location: Rm. 214, Main Bldg. Start date: 19-Mar-87 Environment temperature (avg): 23 °C Environment humidity (avg): 55 % Test equipment: electrical resistance equipment made by Tokyo Industry Co. Definition of Tc: defining the temperature at which voltage became 1 µV/cm as Tc(end) Cooling rate: 3 K/min Test environment: 0.1 MPa (1 atm) He gas

Cautions: Research Data
Resistivity (normal state) for Bi:2223; [Bi-Sr-Ca-Cu-O]
Temperature (K) Resistivity (normal state) (mΩ·cm)
150 2.824
149 2.814
148 2.808
147 2.801
146 2.794
145 2.787
144 2.781
143 2.773
142 2.764
141 2.756
140 2.748
139 2.738
138 2.730
137 2.726
136 2.716
135 2.708
134 2.698
133 2.691
132 2.680
131 2.669
130 2.655
129 2.645
128 2.636
127 2.626
126 2.619
125 2.610
124 2.596
123 2.585
122 2.572
121 2.556
120 2.541
119 2.525
118 2.506
117 2.484
116 2.461
115 2.435
114 2.405
113 2.361
112 2.306
111 2.229
110 2.119
109 1.964
108 1.699
107 1.337
106 1.162
105 1.0659
104 0.970
103 0.860
102 0.722
101 0.577
100 0.433
99 0.301
98 0.190
97 0.107
96 0.0550
95 0.0252
94 0.0101
93 0.00373
92 0.00155
91 0.000723
90 0.000439
89 0.00032
88 0.000403
87 0.000308
86 0.000249
85 0.000296
Measurement Method: Resistivity
Test facility: Chyuo Kenkyu-syo, Mitsubishi Material Location: Rm. 214, Main Bldg. Start date: 19-Mar-87 Environment temperature (avg): 23 °C Environment humidity (avg): 55 % Test equipment: electrical resistance equipment made by Tokyo Industry Co. Definition of Tc: defining the temperature at which voltage became 1 µV/cm as Tc(end) Cooling rate: 3 K/min Test environment: 0.1 MPa (1 atm) He gas

Cautions: Research Data