Material Specification for Bi:2212; [Bi-Sr-Ca-Cu-O]
Process:
Notes:
Formula: Bi2Sr2CaCu2O8
Informal Name: Bi:2212
Chemical Family: Bi-Sr-Ca-Cu-O
Chemical Class: Oxide
Structure Type:
Manufacturer:
Commercial Name:
Production Date:
Lot Number: 92AAGBLA-29
Production Form:
Thermal Conductivity for Bi:2212; [Bi-Sr-Ca-Cu-O]
Temperature (K) |
Thermal Conductivity (W m-1 K-1) |
17.8 |
2.58 |
19 |
2.68 |
22.5 |
2.65 |
22.1 |
2.79 |
24.9 |
2.88 |
27.8 |
2.78 |
29.4 |
2.8 |
30.8 |
2.95 |
33.4 |
2.92 |
35.2 |
3.05 |
37.1 |
2.95 |
39.8 |
2.99 |
41.8 |
2.91 |
46.4 |
2.93 |
50.8 |
2.93 |
56.6 |
2.92 |
60.9 |
2.89 |
66.3 |
2.83 |
70.5 |
2.89 |
74.8 |
2.89 |
80.5 |
2.88 |
86.3 |
2.89 |
90.9 |
2.95 |
95.6 |
2.99 |
101 |
3.03 |
105 |
3.26 |
109 |
3.32 |
114 |
3.38 |
120 |
3.35 |
124 |
3.45 |
128 |
3.59 |
135 |
3.67 |
138 |
3.74 |
145 |
3.83 |
149 |
3.91 |
153 |
4.09 |
160 |
4.17 |
165 |
4.29 |
169 |
4.34 |
174 |
4.43 |
179 |
4.56 |
184 |
4.61 |
189 |
4.63 |
194 |
4.8 |
199 |
4.89 |
Measurement Method: heat-flux
test facility: Faculty of Engineering, Iwate University
location: Lab. of Material Property, Iwate University
start date: 1989/3/2
end date: 1989/3/3
environment temperature: 20 °C
environment humidity: 60 %
test temperature: room temperature
applied pressure: 0.27 mPa (2x10
-6 Torr)
remark on test condition: taking a chamber with room temperature and vacuum (about 0.27 mPa) as adiabatic space, cooling the sample stage to the start temperature, adusting sample temperature with a heater
test equipment (1): helium freezer
maker of test equipment (1): Sumitomo Zyuki
model of test equipment (1): SRD204
test equipment (2): NEC PC-9801RX personal computer
test equipment (3): digital multimeter
maker of test equipment (3): Yokogawa
model of test equipment (3): 2501A
test equipment (4): program power source
maker of test equipment (4): Keithley
model of test equipment (4): Model220
test equipment (5): scanner
maker of test equipment (5): Advantest
model of test equipment (5): TR7200
test equipment (6): CGR resistance thermometer
test equipment (7): Au + 0.07 % Fe-Cr thermocouple
remark on test equipments: using a personal computer to realize the automatic measurement
specimen size: length: 6.4 mm, width: 4.5 mm, thickness: 0.065 mm
distance between specimen and thermometer: 3.15 mm
remark on specimen: fixing sample by using In and ceramic solder, attaching a thermocouple on the sample by using insulation varnish (GE7031).
data comment: saving the test result in a floppy disk, and printing it out after the test is over
remark on test: difficult to handle the specimen because it is a sheet, electrical resistivity being measured
Cautions: Research Data