NIST High Temp. Superconducting Materials (HTS) Database:

NIST Standard Reference Database 62

Last Update to Data Content: 1996

DOI: https://doi.org/10.18434/T4KP8J


Bibliographic Information

Title: Superconducting Properties in Bi2-x-yPbxSbySr2Ca2Cu3Oz
Author(s): I. Hongbao, Z. Weijie, Z. Ling, M. Zhiqiang, L. Biyou, Y. Ming, C. Liezhao, C. Zhaojia, R. Yaozhong, P. Dingkun, et al
Publication: Physica C Volume: 159 Issue: Not Available Year: 1989 Page(s): 665-667
Editor(s): Not Available
Publisher: Elsevier Science Publishers B.V.
Language: English
Notes: et al. = Z. Yuheng
Keywords: Material Specification, Resistance (normal state), Magnetic Susceptibility

Materials and Properties

Bi:2223; [Bi(Pb)-Sr-Ca(Sb)-Cu-O]
Material Specification for Bi:2223; [Bi(Pb)-Sr-Ca(Sb)-Cu-O] Process: Solid State Reaction
Notes: "The samples were prepared by solid state reaction of Bi2O3, CuO, SrCO3, CaCO3, PbO and Sb2O5 in air. The mixtures were heated at 830 °C for 15 h. After grinding and pelletizing into disk shape pellets with (a diameter of) 12 mm, they were sintered... Bi1.6Pb0.4Sr2Ca2Cu3Oz... was sintered at 860 °C for 68 h, at 870 °C for 1 h, and then at 850 °C for 12 h followed by furnace cooling. Bi1.9Sb0.1Sr2Ca2Cu3Oz was sintered at 880 °C for 50 h followed by furnace cooling... Bi1.9-xPbxSb0.1Sr2Ca2Cu3Oz (x= 0.1, 0.3, 0.5) were sintered at 860 °C for 60 h followed by furnace cooling."
Formula: Bi2-x-yPbxSbySr2Ca2Cu3Oz
Informal Name: Bi:2223
Chemical Family: Bi(Pb)-Sr-Ca(Sb)-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:

Resistance (normal state) for Bi:2223; [Bi(Pb)-Sr-Ca(Sb)-Cu-O]
x of Pbx (formula units) y of Sby (formula units) Temperature (K) Resistance (normal state) (mΩ)
0.4 0 107 0.1
0.4 0 109 0.2
0.4 0 112 0.4
0.4 0 114 0.6
0.4 0 115 0.9
0.4 0 116 1.5
0.4 0 116 2.0
0.4 0 122 2.3
0.4 0 128 2.6
0.4 0 134 2.7
0.4 0 143 3.0
0.4 0 153 3.3
0.4 0 160 3.4
0.4 0 168 3.6
0.4 0 178 3.6
0.4 0 186 3.7
0.4 0 194 3.8
0.4 0 198 3.9
0 0.1 78 0.0
0 0.1 82 0.2
0 0.1 85 0.4
0 0.1 87 0.4
0 0.1 91 0.6
0 0.1 101 1.2
0 0.1 105 1.5
0 0.1 110 1.7
0 0.1 112 2.6
0 0.1 113 3.4
0 0.1 114 4.5
0 0.1 115 5.9
0 0.1 115 7.1
0 0.1 118 8.7
0 0.1 119 9.8
0 0.1 120 11.4
0 0.1 124 12.2
0 0.1 129 12.9
0 0.1 132 13.8
0 0.1 138 14.6
0 0.1 145 15.3
0 0.1 150 15.9
0 0.1 159 16.4
0 0.1 166 17.0
0 0.1 170 17.4
0 0.1 174 18.1
0 0.1 180 18.3
0 0.1 183 18.5
0 0.1 194 19.2
0 0.1 198 19.2
0.1 0.1 67 0.2
0.1 0.1 68 0.2
0.1 0.1 70 0.4
0.1 0.1 72 1.2
0.1 0.1 73 2.3
0.1 0.1 74 3.6
0.1 0.1 75 4.3
0.1 0.1 78 5.2
0.1 0.1 79 5.8
0.1 0.1 79 5.8
0.1 0.1 82 6.7
0.1 0.1 83 6.9
0.1 0.1 87 7.1
0.1 0.1 94 7.7
0.1 0.1 97 8.1
0.1 0.1 103 8.8
0.1 0.1 105 9.0
0.1 0.1 110 9.4
0.1 0.1 111 10.6
0.1 0.1 115 11.1
0.1 0.1 120 12.2
0.1 0.1 124 12.7
0.1 0.1 127 12.9
0.1 0.1 133 13.3
0.1 0.1 138 13.7
0.1 0.1 146 14.1
0.1 0.1 150 14.7
0.1 0.1 155 15.2
0.1 0.1 158 15.6
0.1 0.1 165 16.2
0.1 0.1 170 16.9
0.1 0.1 177 17.3
0.1 0.1 181 17.9
0.1 0.1 184 18.3
0.1 0.1 193 19.0
0.1 0.1 199 19.6
0.3 0.1 107 0.3
0.3 0.1 107 0.8
0.3 0.1 108 1.4
0.3 0.1 109 3.0
0.3 0.1 111 4.3
0.3 0.1 112 5.2
0.3 0.1 112 6.5
0.3 0.1 112 7.4
0.3 0.1 113 8.5
0.3 0.1 114 9.1
0.3 0.1 114 10.4
0.3 0.1 115 11.5
0.3 0.1 115 12.8
0.3 0.1 116 14.6
0.3 0.1 118 16.0
0.3 0.1 119 17.2
0.3 0.1 118 18.3
0.3 0.1 121 18.8
0.3 0.1 124 19.7
0.3 0.1 133 20.5
0.3 0.1 137 21.2
0.3 0.1 142 21.9
0.3 0.1 150 23.2
0.3 0.1 157 23.9
0.3 0.1 163 24.3
0.3 0.1 170 25.0
0.3 0.1 176 25.7
0.3 0.1 183 26.6
0.3 0.1 193 27.7
0.5 0.1 104 0.2
0.5 0.1 105 0.9
0.5 0.1 106 1.0
0.5 0.1 107 2.8
0.5 0.1 108 3.5
0.5 0.1 109 4.6
0.5 0.1 109 5.9
0.5 0.1 109 7.4
0.5 0.1 110 9.8
0.5 0.1 112 11.5
0.5 0.1 115 13.5
0.5 0.1 115 14.6
0.5 0.1 117 16.3
0.5 0.1 119 17.6
0.5 0.1 121 19.3
0.5 0.1 129 21.0
0.5 0.1 138 21.7
0.5 0.1 147 22.8
0.5 0.1 151 23.3
0.5 0.1 160 24.1
0.5 0.1 167 25.2
0.5 0.1 172 25.9
0.5 0.1 181 26.7
0.5 0.1 189 27.6
0.5 0.1 195 28.3
0.5 0.1 200 28.3
Measurement Method: Four-probe method
"A four-probe method was employed for resistance measurements."

Cautions: Unevaluated Data
Data were digitized from Figures 1, 2, 3, 4, and 5 of the paper.
Magnetic Susceptibility for Bi:2223; [Bi(Pb)-Sr-Ca(Sb)-Cu-O]
x of Pbx (formula units) y of Sby (formula units) Temperature (K) Magnetic Susceptibility (arbitrary)
0.4 0 77 -10.8
0.4 0 84 -10.1
0.4 0 90 -9.4
0.4 0 92 -8.7
0.4 0 92 -8.0
0.4 0 93 -7.3
0.4 0 94 -6.7
0.4 0 95 -6.0
0.4 0 98 -4.6
0.4 0 102 -3.6
0.4 0 103 -2.4
0.4 0 103 -1.4
0.4 0 105 0
0.4 0 106 0
0.4 0 134 0
0.4 0 149 0
0.4 0 158 0
0.4 0 171 0
0.4 0 184 0
0.4 0 200 0
0 0.1 63 -10.0
0 0.1 64 -8.9
0 0.1 65 -8.3
0 0.1 66 -7.6
0 0.1 67 -6.7
0 0.1 70 -6.3
0 0.1 72 -5.7
0 0.1 75 -5.0
0 0.1 81 -4.4
0 0.1 90 -3.8
0 0.1 96 -3.5
0 0.1 101 -3.3
0 0.1 102 -2.1
0 0.1 106 -2.7
0 0.1 109 -1.5
0 0.1 111 0
0 0.1 113 0
0 0.1 115 0
0 0.1 120 0
0 0.1 130 0
0 0.1 139 0
0 0.1 152 0
0 0.1 161 0
0 0.1 172 0
0 0.1 182 0
0 0.1 192 0
0 0.1 200 0
0.1 0.1 61 -9.3
0.1 0.1 62 -8.5
0.1 0.1 64 -8.0
0.1 0.1 65 -7.4
0.1 0.1 67 -6.9
0.1 0.1 68 -6.3
0.1 0.1 68 -5.7
0.1 0.1 69 -5.1
0.1 0.1 70 -4.4
0.1 0.1 70 -3.7
0.1 0.1 72 -3.0
0.1 0.1 73 -2.5
0.1 0.1 74 -2.1
0.1 0.1 78 -2.0
0.1 0.1 81 -2.0
0.1 0.1 86 -1.8
0.1 0.1 86 0
0.1 0.1 91 0
0.1 0.1 94 0
0.1 0.1 111 0
0.1 0.1 123 0
0.1 0.1 135 0
0.1 0.1 147 0
0.1 0.1 160 0
0.1 0.1 176 0
0.1 0.1 191 0
0.1 0.1 199 0
0.3 0.1 87 -15.8
0.3 0.1 91 -15.5
0.3 0.1 95 -15.1
0.3 0.1 97 -15.0
0.3 0.1 97 -14.0
0.3 0.1 99 -13.0
0.3 0.1 100 -12.5
0.3 0.1 100 -11.8
0.3 0.1 100 -11.0
0.3 0.1 99 -10.5
0.3 0.1 100 -9.5
0.3 0.1 101 -8.7
0.3 0.1 101 -7.7
0.3 0.1 102 -7.1
0.3 0.1 101 -6.5
0.3 0.1 102 -6.0
0.3 0.1 102 -5.1
0.3 0.1 106 -5.0
0.3 0.1 107 -5.0
0.3 0.1 107 -3.8
0.3 0.1 107 -3.3
0.3 0.1 108 -1.9
0.3 0.1 108 -1.0
0.3 0.1 109 -1.0
0.3 0.1 111 0
0.3 0.1 119 0
0.3 0.1 127 0
0.3 0.1 137 0
0.3 0.1 149 0
0.3 0.1 162 0
0.3 0.1 171 0
0.3 0.1 184 0
0.3 0.1 198 0
0.5 0.1 63 -13.0
0.5 0.1 70 -12.4
0.5 0.1 71 -11.9
0.5 0.1 73 -11.1
0.5 0.1 79 -9.6
0.5 0.1 85 -8.0
0.5 0.1 87 -6.0
0.5 0.1 90 -4.1
0.5 0.1 99 -2.7
0.5 0.1 104 -2.5
0.5 0.1 106 -1.2
0.5 0.1 106 -0.5
0.5 0.1 107 -0.1
0.5 0.1 139 -0.1
0.5 0.1 169 -0.1
0.5 0.1 200 -0.1
0.5 0.1 98 -2.3
0.5 0.1 102 -2.3
0.5 0.1 103 -1.7
0.5 0.1 104 -1.0
0.5 0.1 106 0
0.5 0.1 105 0
0.5 0.1 120 0
0.5 0.1 134 0
0.5 0.1 144 0
0.5 0.1 160 0
0.5 0.1 180 0
0.5 0.1 194 0
0.5 0.1 200 0
Measurement Method: Ac susceptibility
"An AC mutual inductance bridge was employed for magnetic susceptibility measurement." No additional measurement details were noted.

Cautions: Evaluated Data