Material Specification for Tl:2223; [Tl-Ba-Ca-Cu-O]
Process: Solid State Reaction
Notes: No processing information was reported.
Formula: Tl2Ba2Ca2Cu3Ox
Informal Name: Tl:2223
Chemical Family: Tl-Ba-Ca-Cu-O
Chemical Class: Oxide
Structure Type:
Manufacturer: Typical
Commercial Name: Typical
Production Date:
Lot Number:
Production Form:
Critical Temperature for Tl:2223; [Tl-Ba-Ca-Cu-O]
Critical Temperature (K) |
119 |
Measurement Method: Electron paramagnetic resonance
"... Diphenylpicrylhydrazyl... was dissolved in acetone to... 10
-2 M concentration... A few milligram sample of the superconductor was then immersed in the... solution and then dried in air. The EPR measurements were made using a Bruker ER 200D EPR spectrometer, operating in the X-band (9.5 GHz). The temperature was controlled to ±0.1 K... All measurements were performed with magnetic field modulation amplitudes in the range of (64-320 A/m = 0.8 - 4 Oe) at a frequency of 100 kHz."
Cautions: Evaluated Data
Penetration Depth for Tl:2223; [Tl-Ba-Ca-Cu-O]
Penetration Depth (σ) |
2520 |
Measurement Method: Electron paramagnetic resonance
"... Diphenylpicrylhydrazyl... was dissolved in acetone to... 10
-2 M concentration... A few milligram sample of the superconductor was then immersed in the... solution and then dried in air. The EPR measurements were made using a Bruker ER 200D EPR spectrometer, operating in the X-band (9.5 GHz). The temperature was controlled to ±0.1 K... All measurements were performed with magnetic field modulation amplitudes in the range of (64-320 A/m = 0.8 - 4 Oe) at a frequency of 100 kHz."
Cautions: Evaluated Data
Material Specification for Bi:2212; [Bi-Sr-Ca-Cu-O]
Process: Solid State Reaction
Notes: No processing information was reported.
Formula: Bi2Sr2CaCu2Ox
Informal Name: Bi:2212
Chemical Family: Bi-Sr-Ca-Cu-O
Chemical Class: Oxide
Structure Type:
Manufacturer: Typical
Commercial Name: Typical
Production Date:
Lot Number:
Production Form:
Critical Temperature for Bi:2212; [Bi-Sr-Ca-Cu-O]
Critical Temperature (K) |
84 |
Measurement Method: Electron paramagnetic resonance
"... Diphenylpicrylhydrazyl... was dissolved in acetone to... 10
-2 M concentration... A few milligram sample of the superconductor was then immersed in the... solution and then dried in air. The EPR measurements were made using a Bruker ER 200D EPR spectrometer, operating in the X-band (9.5 GHz). The temperature was controlled to ±0.1 K... All measurements were performed with magnetic field modulation amplitudes in the range of (64-320 A/m = 0.8 - 4 Oe) at a frequency of 100 kHz."
Cautions: Evaluated Data
Penetration Depth for Bi:2212; [Bi-Sr-Ca-Cu-O]
Penetration Depth (σ) |
2700 |
Measurement Method: Electron paramagnetic resonance
"... Diphenylpicrylhydrazyl... was dissolved in acetone to... 10
-2 M concentration... A few milligram sample of the superconductor was then immersed in the... solution and then dried in air. The EPR measurements were made using a Bruker ER 200D EPR spectrometer, operating in the X-band (9.5 GHz). The temperature was controlled to ±0.1 K... All measurements were performed with magnetic field modulation amplitudes in the range of (64-320 A/m = 0.8 - 4 Oe) at a frequency of 100 kHz."
Cautions: Evaluated Data