Material Specification for Gd:123; [Gd(Pr)-Ba-Cu-O]
Process: Solid State Reaction
Notes: The authors cite A. Kevede et al., Phys. Rev. B, Vol. 40, 4453 (1989), and summarize the procedure as follows. "The samples... were prepared... by a conventional solid-state reaction technique. Stoichiometric amounts of high purity compounds, BaCO3, Y2O3, Pr6O11 and CuO were thoroughly mixed and pelletised. The samples were calcined several times. For x ≥ 0.5, the calcination temperature was 950 °C and for x < 0.5, it was 900 °C... Final heat treatment was given in a flowing oxygen atmosphere at the respective calcination temperatures and the pellets were allowed to stay at 500 °C for 12 h while cooling."
Formula: GdxPr1-xBa2Cu3Oy
Informal Name: Gd:123
Chemical Family: Gd(Pr)-Ba-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:
Critical Temperature for Gd:123; [Gd(Pr)-Ba-Cu-O]
x in Gdx (formula units) |
Critical Temperature (K) |
1.0 |
89 |
0.9 |
80 |
0.8 |
60 |
0.7 |
40 |
0.6 |
23 |
0.5 |
3 |
Measurement Method: Ac susceptibility
"... AC susceptibility... measurements were performed in the temperature interval 12-300 K employing a closed cycle refrigerator..." No additional measurement details were noted.
Cautions: Unevaluated Data
Digitized data were obtained from Figure 2 of the paper.
Resistivity (normal state) for Gd:123; [Gd(Pr)-Ba-Cu-O]
x in Gdx (formula units) |
Temperature (K) |
Resistivity (normal state) (mΩ·cm) |
0.5 |
16 |
2.4 |
0.5 |
12 |
2.5 |
0.5 |
13 |
2.5 |
0.5 |
16 |
2.5 |
0.5 |
18 |
2.5 |
0.5 |
21 |
2.4 |
0.5 |
29 |
2.1 |
0.5 |
38 |
1.9 |
0.5 |
60 |
1.7 |
0.5 |
96 |
1.5 |
0.5 |
163 |
1.6 |
0.5 |
206 |
1.7 |
0.5 |
240 |
1.7 |
0.5 |
272 |
1.8 |
0.5 |
292 |
1.8 |
0.6 |
14 |
0.0 |
0.6 |
19 |
0.0 |
0.6 |
26 |
0.0 |
0.6 |
27 |
0.0 |
0.6 |
32 |
0.3 |
0.6 |
39 |
1.0 |
0.6 |
50 |
1.0 |
0.6 |
98 |
1.0 |
0.6 |
132 |
1.2 |
0.6 |
159 |
1.3 |
0.6 |
181 |
1.4 |
0.6 |
216 |
1.5 |
0.6 |
241 |
1.5 |
0.6 |
267 |
1.6 |
0.6 |
292 |
1.6 |
0.7 |
30 |
0.0 |
0.7 |
36 |
0.0 |
0.7 |
43 |
0.0 |
0.7 |
46 |
0.0 |
0.7 |
47 |
0.2 |
0.7 |
48 |
0.5 |
0.7 |
52 |
0.6 |
0.7 |
76 |
0.7 |
0.7 |
113 |
0.8 |
0.7 |
153 |
1.0 |
0.7 |
181 |
1.1 |
0.7 |
218 |
1.2 |
0.7 |
265 |
1.3 |
0.7 |
292 |
1.4 |
0.8 |
61 |
0.0 |
0.8 |
66 |
0.1 |
0.8 |
67 |
0.3 |
0.8 |
70 |
0.5 |
0.8 |
93 |
0.6 |
0.8 |
128 |
0.7 |
0.8 |
184 |
0.9 |
0.8 |
233 |
1.0 |
0.8 |
269 |
1.2 |
0.8 |
292 |
1.2 |
0.9 |
78 |
0.0 |
0.9 |
82 |
0.0 |
0.9 |
86 |
0.0 |
0.9 |
86 |
0.1 |
0.9 |
87 |
0.3 |
0.9 |
110 |
0.5 |
0.9 |
141 |
0.5 |
0.9 |
175 |
0.6 |
0.9 |
207 |
0.7 |
0.9 |
239 |
0.8 |
0.9 |
272 |
0.9 |
0.9 |
295 |
0.9 |
1.0 |
91 |
0.0 |
1.0 |
93 |
0.0 |
1.0 |
93 |
0.2 |
1.0 |
123 |
0.3 |
1.0 |
169 |
0.4 |
1.0 |
202 |
0.5 |
1.0 |
236 |
0.5 |
1.0 |
268 |
0.6 |
1.0 |
295 |
0.7 |
Measurement Method: Electrical resistance
"Resistivity... measurements were performed in the temperature interval 12-300 K employing a closed cycle refrigerator..." No additional measurement details were noted.
Cautions: Unevaluated Data
Digitized data were obtained from Figure 1 of the paper.
Magnetic Susceptibility for Gd:123; [Gd(Pr)-Ba-Cu-O]
x in Gdx (formula units) |
Temperature (K) |
Magnetic Susceptibility (arbitrary) |
0.6 |
13 |
-1.0 |
0.6 |
19 |
-1.0 |
0.6 |
23 |
-0.9 |
0.6 |
25 |
-0.7 |
0.6 |
26 |
-0.4 |
0.6 |
46 |
-0.4 |
0.6 |
63 |
-0.4 |
0.6 |
82 |
-0.4 |
0.6 |
99 |
-0.4 |
0.7 |
29 |
-1.0 |
0.7 |
35 |
-1.0 |
0.7 |
40 |
-0.9 |
0.7 |
43 |
-0.9 |
0.7 |
44 |
-0.8 |
0.7 |
45 |
-0.5 |
0.7 |
46 |
-0.2 |
0.7 |
63 |
-0.2 |
0.7 |
82 |
-0.2 |
0.7 |
99 |
-0.2 |
0.8 |
41 |
-1.0 |
0.8 |
50 |
-0.9 |
0.8 |
58 |
-0.9 |
0.8 |
61 |
-0.8 |
0.8 |
63 |
-0.5 |
0.8 |
63 |
-0.3 |
0.8 |
82 |
-0.1 |
0.8 |
90 |
-0.1 |
0.8 |
100 |
-0.1 |
0.9 |
42 |
-1.0 |
0.9 |
52 |
-0.9 |
0.9 |
65 |
-0.9 |
0.9 |
77 |
-0.9 |
0.9 |
80 |
-0.8 |
0.9 |
81 |
-0.5 |
0.9 |
82 |
-0.1 |
0.9 |
94 |
-0.1 |
0.9 |
99 |
-0.1 |
1.0 |
62 |
-0.9 |
1.0 |
71 |
-0.9 |
1.0 |
82 |
-0.9 |
1.0 |
87 |
-0.8 |
1.0 |
88 |
-0.6 |
1.0 |
89 |
-0.4 |
1.0 |
89 |
-0.2 |
1.0 |
90 |
0.0 |
1.0 |
100 |
0.0 |
Measurement Method: Ac susceptibility
"... AC susceptibility... measurements were performed in the temperature interval 12-300 K employing a closed cycle refrigerator..." No additional measurement details were noted.
Cautions: Unevaluated Data
Digitized data were obtained from Figure 2 of the paper.
Specific Heat for Gd:123; [Gd(Pr)-Ba-Cu-O]
x in Gdx (formula units) |
Temperature (K) |
Specific Heat (J kg-1 K-1) |
0.1 |
0.4 |
1.0 |
0.1 |
0.6 |
1.4 |
0.1 |
1.6 |
0.8 |
0.1 |
2.8 |
0.9 |
0.1 |
4.7 |
1.8 |
0.1 |
6.7 |
3.4 |
0.1 |
9.7 |
5.8 |
0.1 |
10.6 |
6.8 |
0.1 |
11.7 |
7.2 |
0.1 |
12.8 |
7.0 |
0.1 |
14.1 |
7.1 |
0.1 |
17.7 |
11.1 |
0.1 |
19.4 |
13.8 |
0.2 |
0.5 |
1.1 |
0.2 |
0.5 |
2.3 |
0.2 |
0.6 |
4.4 |
0.2 |
1.0 |
5.7 |
0.2 |
1.7 |
3.6 |
0.2 |
2.5 |
2.4 |
0.2 |
3.4 |
2.1 |
0.2 |
4.5 |
2.4 |
0.2 |
5.5 |
2.6 |
0.2 |
7.7 |
3.3 |
0.2 |
10.1 |
3.9 |
0.2 |
12.3 |
4.7 |
0.2 |
14.8 |
6.3 |
0.2 |
16.3 |
7.5 |
0.2 |
18.7 |
10.1 |
0.2 |
19.7 |
11.6 |
0.4 |
0.5 |
0.7 |
0.4 |
0.6 |
1.8 |
0.4 |
0.7 |
2.2 |
0.4 |
2.1 |
1.2 |
0.4 |
3.1 |
1.2 |
0.4 |
4.1 |
1.6 |
0.4 |
5.0 |
2.1 |
0.4 |
8.0 |
4.6 |
0.4 |
10.1 |
5.9 |
0.4 |
12.0 |
5.4 |
0.4 |
15.1 |
7.2 |
0.4 |
17.4 |
9.4 |
0.4 |
19.6 |
12.1 |
0.7 |
0.5 |
4.4 |
0.7 |
0.7 |
7.2 |
0.7 |
1.0 |
10.2 |
0.7 |
1.1 |
12.4 |
0.7 |
1.2 |
13.6 |
0.7 |
1.4 |
15.1 |
0.7 |
1.8 |
10.9 |
0.7 |
2.2 |
6.6 |
0.7 |
3.7 |
2.8 |
0.7 |
4.3 |
2.4 |
0.7 |
5.9 |
2.1 |
0.7 |
9.1 |
2.3 |
0.7 |
12.4 |
3.3 |
0.7 |
15.8 |
5.3 |
0.7 |
18.4 |
8.1 |
0.7 |
19.9 |
10.1 |
Measurement Method: Adiabatic heat pulse
"Specific heat... measurements were performed... by an adiabatic heat pulse method."
Cautions: Unevaluated Data
No measurement details were noted. Digitized data were obtained from Figure 3 of the paper.