NIST High Temp. Superconducting Materials (HTS) Database:

NIST Standard Reference Database 62

Last Update to Data Content: 1996

DOI: https://doi.org/10.18434/T4KP8J


Bibliographic Information

Title: Thermal Diffusivity and Laser Melting of YBa2Cu3O7 Superconductor
Author(s): J.V. Armstrong, M. McLoughlin, J.G. Lunney, and J.M. Coey
Publication: Superconductor Science and Technology Volume: 4 Issue: Not Available Year: 1991 Page(s): 89-92
Editor(s): Not Available
Publisher: IOP Publishing Ltd
Language: English
Notes: Not Available
Keywords: Material Specification, Density (mass), Thermal Diffusivity

Materials and Properties

Y:123; [Y-Ba-Cu-O]
Material Specification for Y:123; [Y-Ba-Cu-O] Process: Solid State Reaction
Notes: The authors cite J.M.D. Coey et al., J. Solid State Chem., Vol. 77, 204 (1988), and summarize the procedure as follows. "A 0.45 mm thick superconducting sample of YBa2Cu3O7 was prepared by the usual powder sintering method."
Formula: YBa2Cu3O7
Informal Name: Y:123
Chemical Family: Y-Ba-Cu-O
Chemical Class: Oxide
Structure Type: Polycrystalline
Manufacturer: In House
Commercial Name: In House
Production Date:
Lot Number:
Production Form:
Density (mass) for Y:123; [Y-Ba-Cu-O]
Density (g cm-3)
5.5
Measurement Method: Mass density method
"The density... (was) measured by weighing in acetone and air..."

Cautions: Evaluated Data
Thermal Diffusivity for Y:123; [Y-Ba-Cu-O]
Temperature (ambient) (°C) Thermal Diffusivity (10-6 m2 s-1)
25 0.171
50 0.156
75 0.148
100 0.143
200 0.131
400 0.119
600 0.113
Measurement Method: Laser flash method
The authors cite W.J. Parker et al., J. Appl. Phys., Vol. 32, 1679 (1961), and summarize the procedure as follows. "The laser flash method of measuring thermal diffusivity involves using a laser to apply a heat pulse to the front surface of a thin slab of material and measuring the transit time of the heat to the rear surface... The thin superconducting sample was supported on a thermocouple... cross junction inside an evacuated quartz tube placed in a programmable tube furnace. The top surface of the sample was heated with a single 7 ms pulse from a Nd-YAG laser (wavelength = 1.06 µm)... The diffusivity was calculated using the time to half-height, taking into account the effect of cooling..."

Cautions: Evaluated Data
Data were obtained from Equation (6) and Figure 5 in the citation.