Tab Page Summary
Pt4 H3 Na45 (AlO2 )56 (SiO2 )136
platinum clusters on Na-exchanged zeolite Y (Pt4H3Na45(AlO2)56(SiO2)136)
alkali, cluster, molecular sieve
Boyanov B.I., Morrison T.I.
J. Phys. Chem. 100, 16318
Instruction: Click the column to sort in ascending or descending order. Enter a string in the input box in the column header and press the enter to filter the search result in the selected column. Click on the hyperlink in the column for more information. Total Records: 76
Na 11 H3 Na45 (AlO2 )56 (SiO2 )136 KL1 L1 987.90 Na 11 H7 Na41 (AlO2 )56 (SiO2 )136 KL1 L1 987.70 Na 11 H11 Na37 (AlO2 )56 (SiO2 )136 KL1 L1 987.70 Na 11 H20 Na28 (AlO2 )56 (SiO2 )136 KL1 L1 987.90 Na 11 Pt4 H3 Na45 (AlO2 )56 (SiO2 )136 KL1 L1 987.90 Na 11 Pt4 H7 Na41 (AlO2 )56 (SiO2 )136 KL1 L1 987.90 Na 11 Pt4 H11 Na37 (AlO2 )56 (SiO2 )136 KL1 L1 987.90 Na 11 Pt4 H20 Na28 (AlO2 )56 (SiO2 )136 KL1 L1 988.00 O 8 H3 Na45 (AlO2 )56 (SiO2 )136 KL1 L1 507.50 O 8 H7 Na41 (AlO2 )56 (SiO2 )136 KL1 L1 507.20 O 8 H11 Na37 (AlO2 )56 (SiO2 )136 KL1 L1 507.20 O 8 H20 Na28 (AlO2 )56 (SiO2 )136 KL1 L1 507.30 O 8 Pt4 H3 Na45 (AlO2 )56 (SiO2 )136 KL1 L1 507.40 O 8 Pt4 H7 Na41 (AlO2 )56 (SiO2 )136 KL1 L1 507.40 O 8 Pt4 H11 Na37 (AlO2 )56 (SiO2 )136 KL1 L1 507.40 O 8 Pt4 H20 Na28 (AlO2 )56 (SiO2 )136 KL1 L1 507.40 Na 11 H3 Na45 (AlO2 )56 (SiO2 )136 2s 64.40 Na 11 H7 Na41 (AlO2 )56 (SiO2 )136 2s 64.40 Na 11 H11 Na37 (AlO2 )56 (SiO2 )136 2s 64.60 Na 11 H20 Na28 (AlO2 )56 (SiO2 )136 2s 64.50 Na 11 Pt4 H3 Na45 (AlO2 )56 (SiO2 )136 2s 64.40 Na 11 Pt4 H7 Na41 (AlO2 )56 (SiO2 )136 2s 64.40 Na 11 Pt4 H11 Na37 (AlO2 )56 (SiO2 )136 2s 64.40 Na 11 Pt4 H20 Na28 (AlO2 )56 (SiO2 )136 2s 64.40 Na 11 H3 Na45 (AlO2 )56 (SiO2 )136 1s 1072.60 Na 11 H7 Na41 (AlO2 )56 (SiO2 )136 1s 1072.80 Na 11 H11 Na37 (AlO2 )56 (SiO2 )136 1s 1072.80 Na 11 H20 Na28 (AlO2 )56 (SiO2 )136 1s 1072.80 Na 11 Pt4 H3 Na45 (AlO2 )56 (SiO2 )136 1s 1072.60 Na 11 Pt4 H7 Na41 (AlO2 )56 (SiO2 )136 1s 1072.80
Overall Energy Resolution (eV):
Calibration:
Au,Ag,Cu = 84.00,368.27,932.67
Charge Reference:
Adventitious carbon
Energy Scale Evaluation:
Reliable, with one-point correction of energy scale
Comment:
An electron flood gun (Ip = 2 mA) was used for charge compensation. The sample was prepared from commercial Na-exchanged zeolite Y.
Method of Determining Specimen Composition:
Method of Determining Specimen Crystallinity:
Specimen Temperature (K):
300
Go Back