Tab Page Summary
    
    
    
        
        
        
        
                Sirotti F., De Santis M., Rossi G.
 
            
            
            
            
            
            
            
            
                mixed Gaussian/Lorentzian
 
            
            
            
            
            
            
            Anode Material:
                other source
 
            
            Overall Energy Resolution (eV):
                0.38
 
            Calibration:
                FL = Fermi level
 
            Charge Reference:
                Conductor
 
            Energy Scale Evaluation:
                Reliable (reported energy within 300 eV of a reference energy)
Comment:
                Hexagonal closely packed structure. Asymmetry parameter = 0.15.
 
            
            
            
            Method of Determining Specimen Composition:
                 
            Method of Determining Specimen Crystallinity:
                X-ray Diffraction
 
            Specimen Temperature (K):
                300