Name | Description | Type | Additional information |
---|---|---|---|
InsulTradenameID |
Trade name ID |
integer |
None. |
InsulMaterialID | integer |
None. |
|
InsulManufacturerID | integer |
None. |
|
TradeNameId | integer |
None. |
|
ID |
Identification number assigned for a particular data record |
integer |
None. |
Date |
Date of measurement |
string |
None. |
Material |
Generic name of material |
string |
None. |
TradeName |
Trademark, trade name, or some additional material designation, if available |
string |
None. |
Form |
Type of insulation material – blanket, batt, board, block, loose-fill, etc. |
string |
None. |
Description |
Provides additional recorded information for the test specimen, if available |
string |
None. |
SampleNo |
Identification number assigned to a particular test specimen |
string |
None. |
Manufacturer |
Name of manufacturer or third-party source of test specimen |
string |
None. |
Interposed |
Was an auxiliary material placed between the test specimen and apparatus plates? Yes or No |
string |
None. |
SheetMaterial |
Auxiliary material, if present, placed between test specimen and apparatus plates |
string |
None. |
SpecimenTC |
Were auxiliary thermocouples placed between the test specimen and apparatus plates? Yes or No |
string |
None. |
DescTC |
Type of auxiliary thermocouple, if used |
string |
None. |
Mode |
Two-sided or one-sided mode of apparatus operation [default = 2] |
string |
None. |
OtherSpec |
If one-sided, name of other test specimen |
string |
None. |
Density |
Bulk density, including voids, of test specimen in kg∙m-3 or lb∙ft-3 |
decimal number |
None. |
Delta_X |
Thickness of cross-section of test specimen in mm or inches |
decimal number |
None. |
Mean_Temp |
Average of hot and cold plate temperatures in °C or °F |
decimal number |
None. |
Delta_T |
Temperature difference across the test specimen thickness in K or °F |
decimal number |
None. |
k |
Time rate of steady-state heat flow through a unit area of a homogenous material induced by unit temperature gradient normal to the unit area in W∙m-1∙K-1 or Btu∙in∙h-1∙ft-2∙°F-1 |
decimal number |
None. |
Unc |
Uncertainty of measurement, if specified |
string |
None. |
InitMC |
Amount of water, by mass, present in the specimen at test start in %, if available |
decimal number |
None. |
FinalMC |
Amount of water, by mass, present in the specimen at test end in %, if available |
decimal number |
None. |
PreTestCond |
Specimen conditioning (temperature, humidity, time) prior to test, if available |
string |
None. |
Comments |
Comments |
string |
None. |
Apparatus |
Name of the test apparatus used to provide the test data |
string |
None. |
TestMethod |
ASTM test method? |
string |
None. |