Type E Thermocouples -- coefficients of approximate inverse functions giving temperature, t90 , as a function of the thermoelectric voltage, E, in selected temperature and voltage ranges. The functions are of the form:
t90 = d0 + d1 E + d2 E2 + ... dn En
where E is in mV and t90 is in °C.
First script function is to setup the table attributes based on the end-user browser and browser version.
Display the HTML table tag and attributes using JavaScript.
Third function is to display the table caption.
-200 °C to 0 °C
0 °C to 1000 °C
Voltage Range:
-8.825 mV to 0 mV
0 mV to 76.373 mV
d0 =
0.0000000
x100
0.0000000
x100
d1 =
1.6977288
x101
1.7057035
x101
d2 =
-4.3514970
x10-1
-2.3301759
x10-1
d3 =
-1.5859697
x10-1
6.5435585
x10-3
d4 =
-9.2502871
x10-2
-7.3562749
x10-5
d5 =
-2.6084314
x10-2
-1.7896001
x10-6
d6 =
-4.1360199
x10-3
8.4036165
x10-8
d7 =
-3.4034030
x10-4
-1.3735879
x10-9
d8 =
-1.1564890
x10-5
1.0629823
x10-11
d9 =
-3.2447087
x10-14
Error Range:
-0.01 °C to 0.03 °C
-0.02 °C to 0.02 °C
First script function is to display the copyright information.
Second script function is to display the links to NIST home page, NIST Data home page, and NIST other online databases.
Third script function is to display the message identifying NIST as an agency of the U.S. Commerce Department’s Technology Administration.
Fourth script function is to display the message "For comments and questions" and the email address to which comments and questions can be sent.
Fifth script function is to display the date the web page is created.
Sixth script function is to display the date and time the web page is last modified.
Seventh script function is to display the "Section 508 compliant requirements of the Workforce Investment Act & Americans With Disabilities Act" statement.