            methyl iodide/carbon oxide/palladium
 
        
        
            halogenated compound, oxide
 
        
            
                     
            
            
            
            
            
            
            
            
            
            
            
            
            
            
            
            Overall Energy Resolution (eV):
                Calibration:
                Pd3d5 = 335.12
Charge Reference:
                Conductor
Energy Scale Evaluation:
                Reliable, with one-point correction of energy scale
Comment:
                1.5 L CH3I/0.5 L CO/Pd(111). The Pd substrate was cleaned by cycles of O2 treatment, Ar+ ion bombardment, flashing and annealing.
Method of Determining Specimen Composition:
                Method of Determining Specimen Crystallinity:
                Low-energy Electron Diffraction
Specimen Temperature (K):
                100