IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: 1,1-Dichloroethene (1,1-dichloroethylene) with Water.

Components:
   (1) 1,1-Dichloroethene (1,1-dichloroethylene); C2H2Cl2; [75-35-4]  NIST Chemistry WebBook for detail
   (2) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail

Original Measurements:
   DeLassus, P.T.; Schmidt, D.D., J. Chem. Eng. Data 26, 274 (1981).

Variables:
   Temperature = 288 K - 364 K

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°C102 * Mass Fraction w1104 * Mole Fraction x1 (compiler)102 * w1/M1 (compiler) [mol g**-1]
150.244.472.47 x 10-3
170.2554.752.63 x 10-3
20.50.254.652.58 x 10-3
250.2254.192.32 x 10-3
28.50.244.472.47 x 10-3
29.50.2554.752.63 x 10-3
38.50.224.092.27 x 10-3
450.213.912.17 x 10-3
510.234.282.37 x 10-3
550.213.912.17 x 10-3
600.244.472.47 x 10-3
650.2254.192.32 x 10-3
710.2955.493.04 x 10-3
74.50.254.652.58 x 10-3
810.2955.493.04 x 10-3
85.50.376.903.82 x 10-3
90.50.356.523.61 x 10-3
Method/Apparatus/Procedure:
   Approximately 60 cm3 each of 1,1-dichloroethene and water was placed in a steel bomb and immersed in a thermostat bath. After 6-24 hours mechanical shaking, samples were taken from the water phase using a syringe and injected into a  measured aliquot of dimethylacetamide. The solutions were then analyzed using a gas chromatograph technique. Three or more samples were taken at each temperature.

Source and Purity of Materials:
   (1) Source not given, stabilized with monomethyl ether and hydroquinone.
   (2) Distilled.

Estimated Errors:
   Solubility: ± 5 %.
   Temperature: ± 0.5 K (compiler).