NIST Standard Reference Database 106
Solubility System:
Iodobenzene with Water
Components:
(1) Water; H2O; [7732-18-5]
NIST Chemistry WebBook
for detail
(2) Iodobenzene; C6H5I; [591-50-4]
NIST Chemistry WebBook
for detail
Original Measurements:
Jones, J.R.; Monk, C.B., J. Chem. Soc. 1963, 2633-5.
Variables:
Temperature = Temperature
Prepared By:
A. L. Horvath
Experimental Data:
(Notes on the Nomenclature)
t/°C
10
1
* V
1
/V
2
[ml/dm**3]
10
2
* Concentration c
1
[mol dm**-3]
Concent. c
1
Note
10
3
* Mole Fraction x
1
x
1
Note
25
4.9 (a)
2.71
b
3.03
c
30
5.6 (a)
3.09
b
3.47
c
35
6.35 (a)
3.502
b
3.940
c
Notes:
a
Reported.
b
Calculated by F. W. Getzen.
c
Calculated by compiler.
Method/Apparatus/Procedure:
Tritiated water was shaken with iodobenzene in 1:10 volume ratios for 4 hours in flasks placed in a water thermostat bath. The water content was determined by tritium assay of samples taken from the flasks. The count rates were determined using a typical liquid scintillator solution technique.
Source and Purity of Materials:
(1) Tritiated.
(2) Source not known, laboratory grade, dried over CaCI
2
and fractionally distilled before use.
Estimated Errors:
Solubility: ± 5%.
Temperature: ± 0.5 K (compiler).