Home
Introduction
Search Menu
IUPAC Series (PDF)
Reference
Version History
About the Project
Disclaimer
Contact Us
Acknowledgements
IUPAC-NIST Solubility Database
NIST Standard Reference Database 106
Solubility System:
Iodobenzene with Water
Components:
(1) Water; H2O; [7732-18-5]
NIST Chemistry WebBook
for detail
(2) Iodobenzene; C6H5I; [591-50-4]
NIST Chemistry WebBook
for detail
Original Measurements:
Vesala, A., Acta Chem. Scand. 1974, 28A(8), 839-45.
Variables:
Temperature = One temperature
Prepared By:
A. L. Horvath
Experimental Data:
(Notes on the Nomenclature)
t/°C
10
3
* Molality mol
1
/kg
mol
1
/kg Note
10
1
* g
1
/kg
g
1
/kg Note
10
5
* Mole Fraction x
1
x
1
Note
25
1.120
b
2.2845
a
2.0177
a
Notes:
a
Calculated by compiler.
b
Reported.
Method/Apparatus/Procedure:
The iodobenzene was mixed with water in a sealed flask (1) with the aid of a magnetic stirrer for 48 hours in a water bath at constant temperature. After the solution was filtered through a glass-wool plug, the solute was extracted with 2,2,4-trimethylpentene. The optical density of each sample was determined spectrophotometrically (2). Mean and standard deviations were established from five parallel determinations. The reported work was based upon a Ph.D. dissertation (3).
Source and Purity of Materials:
(1) Commercial reagent of analytical grade distilled through a column resulting in a more than 99% pure sample.
(2) Distilled, deionized, and degassed.
Estimated Errors:
Solubility: ± 2.7%.
Temperature: ± 0.05 K.
References:
1
Franks, F.; Gent, M.; Johnson, H. H. J. Chem. Soc. 1963, Part III, 2716-23.
2
Wauchope, R. D.; Getzen, F. W. J. Chem. Eng. Data 1972, 17(1), 38-41
3