IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: 1,3-Dichlorobenzene with Water

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) 1,3-Dichlorobenzene; C6H4Cl2; [541-73-1]  NIST Chemistry WebBook for detail

Original Measurements:
   Chiou, C.T.; Schmedding, D.W.; Manes, M., Environ. Sci. Technol. 1982, 16(1), 4-10.

Variables:
   Temperature = One temperature

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°C101 * g1/V2 [g dm**-3]104 * Concentration c1 [mol dm**-3]Concent. c1 Note105 * Mole Fraction x1x1 Note
251.3419.12b1.648c
Notes:
   a  Calculated by F. W. Getzen.
   b  Reported.
   c  Calculated by compiler.

Method/Apparatus/Procedure:
   An excess of 1,3-dichlorobenzene was equilibrated with water in screwcapped bottles in a reciprocal shaker for 24 hours. After two days settling, samples were taken from the solution for analysis by gas chromatography. The chromatograph was equipped with a Ni63 EC detector. Analyses were continued until a constant concentration was observed.

Source and Purity of Materials:
   (1) Not specified.
   (2) Distilled.

Estimated Errors:
   Solubility: ±5% (compiler).
   Temperature: ±0.5 K.