Home
Introduction
Search Menu
IUPAC Series (PDF)
Reference
Version History
About the Project
Disclaimer
Contact Us
Acknowledgements
IUPAC-NIST Solubility Database
NIST Standard Reference Database 106
Solubility System:
Methylcyclopentane with Water
Components:
(1) Water; H2O; [7732-18-5]
NIST Chemistry WebBook
for detail
(2) Methylcyclopentane; C6H12; [96-37-7]
NIST Chemistry WebBook
for detail
Original Measurements:
McAuliffe, C., J. Phys. Chem. 1966, 70, 1267-75.
Variables:
Temperature = One temperature: 25 °C
Prepared By:
M.C. Haulait-Pirson
Experimental Remarks:
The solubility of methylcyclopentane in water at 25 °C was reported to be 42 mg (1)/kg sln.
The corresponding mole fraction,
x
1
, calculated by the compiler, is 9.0 x 10
-6
.
The same value is also reported in refs 1 and 2.
Experimental Data:
(Notes on the Nomenclature)
Method/Apparatus/Procedure:
n a 250-mL bottle, 10-20 mL of (1) was vigorously shaken for 1 hr, or magnetically stirred for 1 day, with 200 mL of (2) at 25 °C. In the case of shaking, the solution was allowed to stand for 2 days to permit separation of small (1) droplets. Absence of emulsion was checked microscopically. A 50 muL sample of the hydrocarbon-saturated water was withdrawn with a Hamilton syringe and gas liquid chromatographed in conjunction with a flame-ionization detector.
Source and Purity of Materials:
(1) Phillips Petroleum Co.; 99+% purity; used as received.
(2) distilled.
Estimated Errors:
Solubility: 1.6 mg (1)/kg sln (standard deviation from mean)
Temperature: ± 1.5 K
References:
1
McAuliffe, C. Nature (London) 1963, 200, 1092.
2
McAuliffe, C. Am. Chem. Soc. Div. Petrol. Chem. 1964, 9, 275.