IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Toluene with Water

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) Toluene; C7H8; [108-88-3]  NIST Chemistry WebBook for detail

Original Measurements:
   Connolly, J.F., J. Chem. Eng. Data 1966, 11, 13-6.

Variables:
   Temperature = 280-310 °C
   Pressure = 150-600 atm

Prepared By:
   A. Maczynski and Z. Maczynska

Experimental Data:   (Notes on the Nomenclature)
  
Solubility of toluene in water
t/°CPressure [atm]Pressure (compiler) [MPa]g1/100 g solutionMole Fraction x1 (compiler)
28015015.26.80.0141
28025025.36.80.0141
28041041.56.60.0136
28060060.85.80.0119
30017017.214.20.0313
30025025.314.10.0311
30030030.414.00.0308
30516016.218.00.0411
30518018.219.00.0438
30520020.319.50.0452
30525025.319.00.0438
30528528.918.00.0411
31014514.718.00.0411
31015015.219.60.0455
31015515.721.70.0514
31016516.723.90.0578
31017017.226.70.0590
31017517.729.60.0759
31018018.233.10.0882
31018018.236.30.1002
31027027.350.50.1663
31026526.948.60.1560
31026026.346.50.1452
31026026.344.30.1346
31026026.341.90.1236
31026026.339.20.1119
31026026.336.30.1002
31026026.333.10.0882
31027527.929.60.0759
31029529.926.70.0665
31032532.923.80.0575
31040541.019.50.0452
31045546.111.00.0411
Method/Apparatus/Procedure:
   Measurements were carried out in a 100 mL stainless-steel cell. The cell was loaded with 15 g (2) and brought to temperature. Mixing was started anf (1) wa injected until either a cloud or a small droplet of a second phase appeared at the top of the cell. Then mercury was injected to change pressure, more (1) was injected and the measurement was repeated.

Source and Purity of Materials:
   (1) Phillips reagent grade; better than 99.8%; used as received.
   (2) distilled and dearated.

Estimated Errors:

   Temperature: ± 0.02 K
   Pressure: ± 2 atm.