Home
Introduction
Search Menu
IUPAC Series (PDF)
Reference
Version History
About the Project
Disclaimer
Contact Us
Acknowledgements
IUPAC-NIST Solubility Database
NIST Standard Reference Database 106
Solubility System:
Naphthalene with Water
Components:
(1) Water; H2O; [7732-18-5]
NIST Chemistry WebBook
for detail
(2) Naphthalene; C10H8; [91-20-3]
NIST Chemistry WebBook
for detail
Original Measurements:
Variables:
Prepared By:
Experimental Data:
(Notes on the Nomenclature)
Method/Apparatus/Procedure:
The dynamic coupled column liquid chromatography (DCCLC) method was based on generating saturated solutions by pumping water through a column packed with glass beads that have been coated with the component (1) (generator column). The concentration of (1) in the effluent of the generator column was measured by a modification of the coupled column liquid chromatographic process that has been described in ref 1.
Source and Purity of Materials:
(1) commercial product; less than 3% impurities.
(2) distilled over KMnO
4
and NaOH and passed through a column packed with XAD-2 (Rohm and Hass, philadelphia, Pa).
Estimated Errors:
Solubility: ± 0.23 mg(1)/100 kg(2) (standard deviation)
Temperature: ± 0.05°C
References:
1
May, W.; Chesler, S.; Cram, S.; Gump, B.; Hertz, H.; Enagonio, D.; Dyszel, S., J. Chromatogr. Sci. 1975, 13, 535.