IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Anthracene with Water

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) Anthracene; C14H10; [120-12-7]  NIST Chemistry WebBook for detail

Original Measurements:
   

Variables:


Prepared By:
   

Experimental Data:   (Notes on the Nomenclature)
  
Solubility of anthracene in water
t/°C106 * g1/kg106 * g1/100 g solution (compiler)109 * Mole Fraction x1 (compiler)
5.212.7 ± 0.41.271.28
10.017.5 ± 0.31.751.77
14.122.2 ± 0.12.222.24
18.329.1 ± 0.62.912.94
22.437.2 ± 1.13.723.76
24.643.4 ± 0.14.344.39
25.044.6 ± 0.24.464.51
28.755.7 ± 0.75.575.63
29.057.0 ± 3.05.75.76
Method/Apparatus/Procedure:
   The dynamic coupled column liquid chromatography (DCCLC) method was based on generating saturated solutions by pumping water through a column packed with glass beads that have been coated with the component (1) (generator column). The concentration of (1) in the effluent of the generator column was measured by a modification of the coupled column liquid chromatographic process that has been dexcribed in ref 1.

Source and Purity of Materials:
   (1) commercial product; less than 3% impurities.
   (2) distilled over KMnO4 and NaOH and passed through a column packed with XAD-2 (Rohm and Hass, Philadelphia, Pa.)

Estimated Errors:
   Solubility: stand. dev. See above
   Temperature: ± 0.05°C

References:
   1May, W.; Chesler, S.; Cram, S.; Gump, B.; Hertz, H.; Enagonio, D .; Dyszel, S., J. Chromatogr. Sci. 1975, 13, 535.