IUPAC-NIST Solubility Database
NIST Standard Reference Database 106
Solubility System:
2-Methylanthracene with Water
Components:
(1) Water; H2O; [7732-18-5]
NIST Chemistry WebBook
for detail
(2) 2-Methylanthracene; C15H12; [613-12-7]
NIST Chemistry WebBook
for detail
Original Measurements:
Variables:
Prepared By:
Experimental Data:
(Notes on the Nomenclature)
Solubility of 2-methylanthracene in water
t/°C
g
1
/100 g solution (compiler)
g
1
/100 g soln. Note (compiler)
10
9
* Mole Fraction x
1
(compiler)
6.3
0.706
6
0.661
9.1
0.848
6
0.794
10.8
0.943
6
0.883
13.9
1.11
6
1.04
18.3
1.45
6
1.36
23.1
1.91
6
1.79
25.0
2.13
6
1.99
27.0
2.42
6
2.27
31.1
3.21
6
3.01
Method/Apparatus/Procedure:
The dynamic coupled column liquid chromatography (DCCLC) method was based on generating saturated solutions by pumping water through a column packed with glass beads that have been coated with the component (1) (generator column). The concentration of (1) in the effluent of the generator column was measured by a modification of the coupled column liquid chromatographic process that has been described in ref 1.
Source and Purity of Materials:
(1) Commercial product; less than 3% impurities.
(2) Distilled over KMnO
4
and NaOH and passed through a column packed with XAD-2 (Rohm and Hass, Philadelphia, Pa).
Estimated Errors:
Solubility: Stand. dev. See above.
Temperature: ± 0.05 °C
References:
1
May, W.; Chesler, S.; Cram, S.; Gump, B.; Hertz, H.; Enagonio, D.; Dyszel, S.,
J. Chromatogr. Sci.
1975,
13
, 535.