IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Fluoranthene with Water

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) Fluoranthene; C16H10; [206-44-0]  NIST Chemistry WebBook for detail

Original Measurements:
   

Variables:


Prepared By:
   

Experimental Data:   (Notes on the Nomenclature)
  
Solubility of fluoranthene in water
t/°C103 * g1/kg (compiler)g1/100 g solution (compiler)g1/100 g soln. Note (compiler)108 * Mole Fraction x1 (compiler)
250.2062.0651.83
290.2642.6452.35
Method/Apparatus/Procedure:
   The dynamic coupled column liquid chromatography (DCCLC) method was based on generating saturated solutions by pumping water through a column packed with glass beads that have been coated with the component (1) (generator column). The concentration of (1) in the effluent of the generator column was measured by a modification of the coupled column liquid chromatographic process that has been described in ref 1.

Source and Purity of Materials:
   (1) Commercial product; less than 3% impurities.
   (2) Distilled over KMnO4 and NaOH and passed through a column packed with XAD-2 (Rohm and Hass, Philadelphia, Pa).

Estimated Errors:
   Solubility: ± 0.002 mg(1)/kg(2) (standard deviation)
   Temperature: ± 0.05 °C

References:
   1May, W.; Chesler, S.; Cram, S.; Gump, B.; Hertz, H.; Enagonio, D.; Dyszel, S., J. Chromatogr. Sci. 1975, 13, 535.