IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Anthracene with t-Butylcyclohexane and 2,2,4-Trimethylpentane

Components:
   (1) 2,2,4-Trimethylpentane; C8H18; [540-84-1]  NIST Chemistry WebBook for detail
   (2) Anthracene; C14H10; [120-12-7]  NIST Chemistry WebBook for detail
   (3) t-Butylcyclohexane; C10H20; [3178-22-1]  NIST Chemistry WebBook for detail

Original Measurements:
   Zvaignze, A.I.; Acree, W.E., Jr., J. Chem. Eng. Data 1994, 39, 117-118.

Variables:
   Temperature = 298 K
   Concentration = Solvent composition

Prepared By:
   W. E. Acree, Jr.

Experimental Data:   (Notes on the Nomenclature)
  
t/°CMole Fraction x1Mole Fraction x3x3s
25.00.0019780.00000.0000
25.00.0018990.10910.1093
25.00.0018090.21110.2115
25.00.0016510.38560.3862
25.00.0015360.50410.5049
25.00.0014290.61330.6142
25.00.0012490.80890.8099
25.00.0011630.89510.8961
25.00.0010740.99891.0000
Notes:
     x3(s): initial mole fraction of binary solvent mixture; x1: mole fraction solubility of the solute; x3: mole fraction of component 3 in the ternary solution.

Method/Apparatus/Procedure:
   Constant temperature bath, calorimetric thermometer, and an ultraviolet/visible spectrophotometer. Binary solvent mixtures were prepared by weight. Excess solute and solvent placed in amber glass bottles and allowed to equilibrate for several days at constant temperature. Attainment of equilibrium verified by  several repetitive measurements and by approaching equilibrium from supersaturation. Aliquots of saturated solutions transferred through a coarse filter into tared volumetric flasks, weighed and diluted with methanol. Concentrations  determined spectrophotometrically at 356 nm.

Source and Purity of Materials:
   (1) Gold Label, 99.9+ %, Aldrich Chemical Company, Milwaukee, Wisconsin, USA, was used as received.
   (2) 99 %, Aldrich Chemical Company.
   (3) HPLC Grade, 99.7 %, Aldrich Chemical Company.
   Components 2 and 3 were stored over molecular sieves and distilled shortly before use.

Estimated Errors:
   Solubility: x3(s): ± 0.0001. x1: ± 1 % (relative error).
   Temperature: T/K: ± 0.05.

References:
   1W.E. Acree, Jr.