IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Phenanthrene with n-Heptane

Components:
   (1) Phenanthrene; C14H10; [85-01-8]  NIST Chemistry WebBook for detail
   (2) n-Heptane; C7H16; [142-82-5]  NIST Chemistry WebBook for detail

Original Measurements:
   Doane, E.P.; Drickamer, H.G., J. Phys. Chem. 1955, 59, 454-457.

Variables:
   Temperature = 298 K
   Concentration = Pressure

Prepared By:
   W.E. Acree, Jr.

Experimental Data:   (Notes on the Nomenclature)
  
Pressure [atm]Mole Fraction x1Mole Fraction x2
10.04010.9599
5000.03210.9679
9000.02920.9708
10000.02720.9728
20000.01840.9816
34300.01110.9889
50000.00840.9916
70000.00520.9948
Method/Apparatus/Procedure:
   Constant temperature bath, analytical balance and high pressure equipment.
Excess solute and solvent allowed to equilibrate in a specially designed high pressure cell at constant temperature for 20-24 hours. Known amount of saturated solution removed, solvent evaporated to dryness, and concentration determined from weight of solid residue.

Source and Purity of Materials:
   (1) Purest grade, Eastman Kodak Chemical Company, Rochester, New York, USA, was used as received.
   (2) Pure grade, Phillips Petroleum, was dried over phosphorous pentoxide and distilled.

Estimated Errors:

   Temperature: T/K: ± precision 0.1. x1: ± 1-3 % at atmospheric pressure, and ± 10 % at the higher pressures.