IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Phenanthrene with 3,4-Dinitro-1-methylbenzene

Components:
   (1) Phenanthrene; C14H10; [85-01-8]  NIST Chemistry WebBook for detail
   (2) 3,4-Dinitro-1-methylbenzene; C7H6N2O4; [610-39-9]  NIST Chemistry WebBook for detail

Original Measurements:
   Kremann, R., Monatsch. Chem. 1908, 29, 863-890.

Variables:
   Temperature = Temperature

Prepared By:
   W.E. Acree, Jr.

Experimental Data:   (Notes on the Nomenclature)
  
T/KMole Fraction x1Mole Fraction x2Comment(s)
332.20.0001.000Solid Phase (2)
324.70.1250.875Solid Phase (2)
322.20.1470.853Solid Phase (2)
320.20.1700.830Solid Phase (2)
317.20.2150.785Solid Phase (2)
313.20.2760.724Solid Phase (2)
309.20.3210.679Solid Phase (2)
307.20.3280.672Solid Phase (2)
316.00.4190.581Solid Phase (1)
324.10.4530.547Solid Phase (1)
328.20.4960.504Solid Phase (1)
330.80.5110.489Solid Phase (1)
334.20.5430.457Solid Phase (1)
342.20.5940.406Solid Phase (1)
350.20.6660.334Solid Phase (1)
355.20.7180.282Solid Phase (1)
360.70.7860.214Solid Phase (1)
365.40.8410.159Solid Phase (1)
369.70.8910.109Solid Phase (1)
372.70.9400.060Solid Phase (1)
376.71.0000.000Solid Phase (1)
Notes:
     Compiler: Eutectic point occurs at about x1 = 0.341 and T/K = 308.

Method/Apparatus/Procedure:
   Binary mixtures prepared by weight. While the experimental details were not given in the paper, compiler speculates (based upon quantity of material used) that the sample was sealed in a glass container, temperature slowly varied, and the phase diagram determined by visually noting the temperature at which the last/first crystal of solid disappeared/appeared.

Source and Purity of Materials:
   (1) Purity and chemical source were not specified in paper.
   (2) Purity and chemical source were not specified in paper.

Estimated Errors:

   Temperature: T/K: precision ± 0.2 (compiler). x1: ± 0.002 (compiler).