IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Bromodichloromethane with Water

Components:
   (1) Myponga water; ; []  NIST Chemistry WebBook for detail
   (2) Bromodichloromethane; CHBrCl2; [75-27-4]  NIST Chemistry WebBook for detail

Original Measurements:
   Nicholson, B.C.; Maguire, B.P.; Bursill, D.B., Environ. Sci. Technol. 1984, 18, 518-21.

Variables:
   Temperature = 293 K

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°CHenry's law constant [m**3 atm mol**-1]102 * Mass Fraction w1 (compiler) 103 * Mole Fraction x1 (compiler)
201.5 x 10-32.2392.515
Method/Apparatus/Procedure:
   The apparatus consisted of a stripping vessel similar to that described by Mackay et al. (ref. 1). The air entered through the top of the vessel and the diffuser was close to the bottom. The solution was added to the stripping vessel and the desired flow  rate maintained. Samples of the solution being stripped were taken for analysis. After samples were extracted, they were analyzed using a gas chromatograph equipped with a capillary column.

Source and Purity of Materials:
   (1) Source and purity not given.
   (2) pH = 7.6, 370 mg salt/dm3, 60 mg CaCO3/dm3, 10 mg organic carbon/dm3.

Estimated Errors:
   Solubility: Not specified.
   Temperature: ± 0.1 K.

References:
   1 Mackay, D.; Shiu, W. Y.; Sutherland, R. P. Environ. Sci. Technol. 1979, 13, 333.