IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Dibromochloromethane with Water

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) Dibromochloromethane; CHBr2Cl; [124-48-1]  NIST Chemistry WebBook for detail

Original Measurements:
   McNally, M.E.; Grob, R.L., J. Chromatogr. 1984, 284, 105-16.

Variables:
   Temperature = 303 K

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°Cg1/V2 [g m**-3]102 * Mass Fraction w1 (compiler) 104 * Mole Fraction x1 (compiler)
3025090.25142.179
Method/Apparatus/Procedure:
   Standard dibromochloromethane solutions of increasing concentration were prepared in volumetric flasks as described elsewhere (ref. 1). The aqueous organic liquid phase was 25 ml and the vapor phase above the mixture was 35 ml. The system was allowed to  reach equilibrium in a constant temperature bath and then a sample was injected into the gas chromatograph. Values reported are an average of at least 5 measurements.

Source and Purity of Materials:
   (1) Chemical Service, West Chester, PA., USA, purest grade available.
   (2) Distilled and run through two Barnstead purification cartridges.

Estimated Errors:
   Solubility: ± 3.47 % std. dev.
   Temperature: ± 0.5 K (compiler).

References:
   1 McNally, M. E.; Grob, R. L. J.Chromatogr. 1983, 260, 23.