IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Trichloromethane (chloroform) with Water

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) Trichloromethane (chloroform); CHCl3; [67-66-3]  NIST Chemistry WebBook for detail

Original Measurements:
   Reinders, W.; De Minjer, C.H., Recl. Trav. Chim. Pays-Bas 1947, 66, 573-604.

Variables:
   Temperature = 273 K - 333 K

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°C102 * Mass Fraction w1102 * Mass Fraction w2103 * Mole Fraction x1 (compiler)103 * Mole Fraction x2 (compiler)
00.980.11.496.59
250.90-1.37-
420.71-1.08-
600.750.171.1411.2
Method/Apparatus/Procedure:
   The saturation between trichloromethane and water took place in a water bath. The composition of both the organic and water phases were determined from their density and refractive index. The constant density and refractive index calibration curves were established by using  several synthetic mixtures.

Source and Purity of Materials:
   (1) Commercial grade, washed with H2SO4 and K2CO3 solutions, followed by distillation before use.
   (2) Distilled.

Estimated Errors:
   Solubility: Not specified.
   Temperature: ± 0.05 K (compiler).