IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Trichloromethane (chloroform) with Water

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) Trichloromethane (chloroform); CHCl3; [67-66-3]  NIST Chemistry WebBook for detail

Original Measurements:
   Tettamanti, K.; Nogradi, M.; Sawinsky, J., Periodica Polytech. 1960, 4, 201-18.

Variables:
   Temperature = 293 K

Prepared By:
   Z. Maczynska

Experimental Data:   (Notes on the Nomenclature)
  
t/°C102 * Mass Fraction w1102 * Mass Fraction w2103 * Mole Fraction x1 (compiler)103 * Mole Fraction x2 (compiler)
200.827.0 x 10-21.254.62
Method/Apparatus/Procedure:
   Turbidimetric titrations were used for both the aqueous and the organic phases. First, trichloromethane was titrated with water from a microburet until the appearance of turbidity. Then, water was titrated with trichloromethane. The amount of trichloromethane  or water in the flask was weighted to an accuracy of 0.01 g. The temperature was maintained constant by using ultrathermostat bath. The trichloromethane-water-caprolactam ternary system was also studied.

Source and Purity of Materials:
   (1) Source and purity not given.
   (2) Distilled (compiler).

Estimated Errors:
   Solubility: ± 1.0 %.
   Temperature: ± 0.1 K.